液氮罐 CryoPro BR系列
产品简介
VWR BR系列在设计上结合盒装小瓶贮藏与液氮低损耗的特点,使该系列储藏罐更适合于中等数量甚至大量冷冻贮藏的需要,盒装小瓶冷冻贮藏方法可快速、准确的清点以及恢复样品,BR-1型贮罐可装25个纸制或塑料盒,而BR-2、BR-3和BR-4可装100个
产品详细信息
Combining the convenience of box vial storage with the economy of a low nitrogen loss design, the BR Series provides the perfect solution for medium to large storage needs. Vial storage in boxes (sold separately) allows for quick and accurate inventorying and recovery of specimens. The BR-1 model can hold 25-cell cardboard or plastic boxes. The BR-2, BR-3, and BR-4 models can hold 100-cell cardboard or plastic boxes.
Sturdy five-wheel rollerbases are available for safely moving full tanks. An optional low liquid level alarm (55709-276) helps protect against accidental warmups. The phase separator (55709-278) can be attached to the stainless steel transfer hose (55709-244) for increased efficiency and safety when transferring liquid nitrogen.
CryoRetriever claw-style tool (82017-944) is specifically designed for retrieving boxes, vials, and frames from cryopreservation tanks. Exclusive sealed center shaft prevents hazardous spurting of LN2 that can occur with a hollow shaft retrieval claw.
|
BR-1 |
BR-2 |
BR-3 |
BR-4 |
Capacity 容量 |
|
|
|
|
Vials: 瓶子: |
875 |
2500 |
5000 |
7000 |
Boxes: 盒子: |
35 |
25 |
50 |
70 |
Racks: 支架: |
7 |
5 |
5 |
7 |
Boxes per Rack: 每个支架的盒子数 |
5 |
5 |
10 |
10 |
Ordering Information: The BR-1 and BR-4 models include 7 racks. The BR-2 and BR-3 models include 5 racks.
Description |
Static Evaporation |
Liquid Nitrogen |
Neck Diameter, |
Overall Height x |
VWR Catalog # |
Unit |
BR-1 Rack System |
0.39 |
47 |
12.7 (5) |
67.3 x 50.8 (261/2 x 20) |
55709-208 |
Each |
BR-2 Rack System |
0.85 |
61 |
21.6 (81/2) |
68 x 55.9 (263/4 x 22) |
55709-210 |
Each |
BR-3 Rack System |
0.99 |
121 |
21.6 (81/2) |
95 x 55.9 (373/8 x 22) |
55709-212 |
Each |
BR-4 Rack System |
0.99 |
175 |
21.6 (81/2) |
95 x 65.5 (373/8 x 263/16) |
55709-214 |
Each |
Accessories | ||||||
5-Wheel Rollerbase for BR-1 Rack System |
— |
— |
— |
55709-262 |
Each | |
5-Wheel Rollerbase for BR-2 Rack System |
— |
— |
— |
55709-264 |
Each | |
5-Wheel Rollerbase for BR-3 Rack System |
— |
— |
— |
55709-266 |
Each | |
5-Wheel Rollerbase for BR-4 Rack System |
— |
— |
— |
55709-268 |
Each | |
|
|
|
|
|
Case of 204 | |
Each | ||||||
25-Cell Plastic Box, |
— |
— |
— |
55709-260 |
Each | |
|
|
|
|
|
Case of 120 | |
Each | ||||||
100-Cell Plastic Box, |
— |
— |
— |
55709-256 |
Each | |
Low Liquid Level Alarm |
— |
— |
— |
55709-276 |
Each | |
LN2 Transfer Hose, Stainless Steel, |
— |
— |
— |
55709-244 |
Each | |
Phase Separator for Safe Liquid Transfer |
— |
— |
— |
55709-278 |
Each | |
Liquid Level Measuring Stick |
— |
— |
— |
55709-246 |
Each | |
Cryo-Gloves*, Large, Mid-Arm |
— |
— |
— |
55709-248 |
Each | |
CryoRetriever Tongs, |
— |
— |
— |
82017-944 |
Each |