OPERATION MODE |
Independent | (0~30V/0~6A) x 2, (5V/3A Max.) x 1 |
Series | 60V 6A |
Parallel | 30V 12A |
5V FIXED OUTPUT |
Line Regulation | <5mV |
Load Regulation | <10mV |
Ripple & Noise | <2mVrms |
Voltage Accuracy | 5V±0.25V |
Output Current | 3A |
TRACKING OPERATION |
Tracking Error | <0.5% + 10mV of the master |
Series Regulation | <300mV |
CONSTANT VOLTAGE OPERATION |
Line Regulation | <0.01%+3mV |
Load Regulation | <0.01% + 3mV (ratingcurrent<3A) <0.02% + 5mV (rating current<10A) |
Ripple & Noise | <1mVrms 5Hz ~ 1MHz |
Current Output | <100μS ( 50% load change, minimum load0.5A ) |
CONSTANT CURRENT OPERATION |
Line Regulation | <0.2% + 3mA |
Load Regulation | <0.2% + 3mA |
Ripple & Noise | <3mArms |
METER |
Type | 3 1/2 digit 0.5" LED display |
Accuracy | ±( 0.5% of rdg + 2 digits ) |
INSULATION |
Chassis and Terminal | 20MΩ or above (DC 500V) |
Chassis and AC Cord | 30MΩ or above (DC 500V) |
POWER SOURCE | |
| AC 100V/120V/220V/240V ±10%, 50/60Hz |
ACCESSORIES |
| User manual x 1 Power cord x 1 Test lead GTL-104 x 2 (<10A), GTL-105 x1(<3A) European test lead GTL-204 x 2(<10A), GTL-203 x1(<3A) |
DIMENSIONS &WEIGHT | |
| 255(W) x 145(H) x 346(D)mm Approx. 18.5kg |