Hypot Plus II 5560DT AC/DC高压检测仪 安规分析仪租赁 华仪7440 华仪7420 华仪7430
产品简介
Hypot Plus II 5560DT AC/DC高压检测仪 安规分析仪租赁 华仪7440 华仪7420 Hypot Plus II 5560DT AC/DC高压检测仪 安规分析仪租赁 华仪7440 华仪7420
产品详细信息
Associated Research 5560DT Hypot Plus II AC/DC Withstand Voltage Tester
Shipping Details: Shipping weight : 28 lbs. Box size 22" x 22" x 10".
Inventory Code : SO-K-AR_5560DT_Hypot-1
专业销售/收购/维修、租赁二手仪器设备
手机:/李汉明,曾小姐,QQ308966
Input | 115 VAC (± 15%), 47 Hz - 63 Hz, Single Phase 230 VAC (± 15%), 47 Hz - 63 Hz, Single Phase User Selectable | |
Fuse | 115/230 VAC-5 Amp | |
Output Rating | 5 kV AC @ 20 mA | |
6 kV DC @ 6 mA | ||
Output Adjustment | 0 - 5 kV AC (6 kV DC), 10 volt/steps | |
0-20.00 mA AC & 6 mA DC, 0.01 mA/steps | ||
High Trip Range | 0.05 - 20.00 mA AC & 0.02-6.00 mA DC | |
Accuracy ±(2% of setting + 0.02 mA) | ||
Low Trip Range | 0.00 - 19.99 mA AC & 0.00-5.99 mA DC | |
Accuracy ±(2% of setting + 0.02 mA) | ||
Continuity Trip | 1.1 ohms maximum at 0.1 Amp | |
Failure Detector | Audible & Visual displayed on LCD meter holds breakdown voltage and leakage current reading after failure | |
Voltage Display | 3 Digits, 6.00 kV Full Scale, LCD Display | |
Accuracy: Readings ± (2% of reading + 10 volts) Settings ± (2% of reading + 5 volts) | ||
Current Display | ||
4 Digits, 20.00 mA Full Scale, LCD Display Accuracy: Readings ± (2% of reading + 0.02 mA) | ||
DC Output Ripple | ≤5% (6 kV DC, 6 mA) | |
AC Output Waveform | Sine wave, Distortion² 1% | |
AC Output Frequency | 50 Hz or 60 Hz, User Selectable | |
Output Regulation | 1% of Setting + 5 Volts | |
Dwell Timer | 0.5 - 999.9 seconds in 0.1 second increments or continuous, accuracy ±(0.1% of reading + 0.05 seconds) | |
Ramp Timer | 0.5 - 99.9 seconds in 0.1 second increments accuracy ±(0.1% of reading + 0.05 seconds) | |
Remote (PLC) | Inputs-Test, Reset, Memory Select Outputs-Pass, Fail, Remote Alarm, Test in Process | |
Memory | Allows storage of up to 10 different test programs | |
Security | User selectable password to avoid unauthorized access to test setup program | |
Line Cord | Detachable 7 ft. (2.13 m) power cable terminated in a three prong grounding plug | |
Terminations | 5 ft. (1.52 m) high voltage and return leads with clip and a standard U.S. style (NEMA 5-15) remote receptacle box for testing items terminated with a line cord. International plugs also available | |
Mechanical | Bench or rack mount (2U height) with tilt up front feet | |
Dimensions: 17" x 3.5" x 16.5" (W x H x D) | ||
Weight | 25 lbs. (11.34 kg) net | |
Environmental | Operating Temperature 32° -113° F (0° - 45°C) Relative Humidity - 0 to 95% | |
Calibration |
Traceable to National Institute of Standards and Technology (NIST). Calibration controlled by software. Adjustments are made through front panel keypad in a restricted access calibration mode. Calibration information stored in non-volatile memory |