CCS1 series
|
|
|
|
-
High capacity general purpose load cell
|
|
|
|
Rated capacity
|
490.3 kN {50 tf}~2.942 MN {300 tf}
|
Safe overload
|
150 %R.C.
|
Ultimate overload
|
200 %R.C.
|
Rated output
|
2 mV/V±0.02 mV/V
|
Non-linearity
|
0.3 %R.O.
|
Hysteresis
|
0.3 %R.O.
|
Repeatability
|
0.15 %R.O.
|
Excitation, recommended
|
12 V or less
|
Excitation, maximum
|
20 V
|
Zero balance
|
±0.02 mV/V
|
Input resistance
|
350 Ω±3.5 Ω
|
Output resistance
|
350 Ω±5 Ω
|
Insulation resistance
|
2 000 MΩ or more (DC50 V) (between bridge and main body)
|
Temp. range, compensated
|
-10 ℃ ~ 70 ℃
|
Temp. range, safe
|
-20 ℃ ~ 100 ℃
|
Temp. effect on zero
|
0.05 %R.O./10 ℃
|
Temp. effect on output
|
0.1 %LOAD/10 ℃
|
Cable
|
φ10, 4 -cores shielded 3 m cable directly attached,
Y-crimp type terminal lugs are attached at cable end.
|
Class of protection
|
IP64
|
Material of element
|
Alloy steel
|
Paint
|
Painted by epoxy resin
(Munsell 6GY3.5/2 half-polished resemblance color)
|
Durability
|
1 000 000 times with rated load applied.
|
|
|
|
Expansion plate, Bearing plate, Mounting plate
|
|
|
|
Parts No.
|
Rated capacity
|
Natural frequency
|
Rated displacement
|
Weight
|
CCS1-50T
|
490.3 kN {50 tf}
|
9 700 Hz
|
0.16 mm
|
Approx.10 kg
|
CCS1-100T
|
980.7 kN {100 tf}
|
8 200 Hz
|
0.19 mm
|
Approx.18 kg
|
CCS1-200T
|
1.961 MN {200 tf}
|
6 900 Hz
|
0.23 mm
|
Approx.34 kg
|
CCS1-300T
|
4.903 MN {500 tf}
|
4 800 Hz
|
0.34 mm
|
Approx.50 kg
|
|
|