示波器(100MHz) OS-5100
产品简介
100MHz, 2Ch, Dual trace, Delay sweep function DC to 100MHz bandwidth, 2 channels, Dual trace 6" rectangular CRT with internal graticule Wide dynamic range even at high frequency ALT trigge
产品详细信息
CRT |
- Configuration and useful screen :
6 inch rectangular screen with internal graticule, 8X10div. (1div = 1cm) marking for measurement of rise time, 2mm subdivisions along the central axis. - Acceleration potential : +10.5kv approx.(ref. Cathode) - Phosphor : P31 - Focusing : provided - Trace rotation : provided - Intensity control : provided |
Z-AXIS INPUT(INTENSITY MODULATION)
|
- Input signal : positive going signal decreases +5Vp-p or more signal cases
intensity noticeable modulation at normal intensity setting - Bandwidth : DC to 3.5MHz(-3dB) - Coupling : DC - Input impedance : 17~22kз typical - Maximum input voltage : 20V(DC + peak AC) |
VERTICAL
DEFLECTION |
- DC coupled(-3dB) : DC to 100MHz normal / DC to 20MHz magnified
- AC coupled(-3dB) : 10Hz to 100MHz normal / 10Hz to 20MHz magnified - Modes : CH1, CH2, ADD, CHOP, ALT - Deflection factor (normal): 2mV/div. to 5V/div. in 11 calibrated steps of 1-2-5 sequence. Continuously variable between steps at least 1:2.5 X 5. - Accuracy : normal ±3% - Input impedance : approx. 1Mз in parallel with 25pF - Maximum input voltage : direct 250V (DC + peak AC) - Input coupling : AC, GND, DC - Rise time : 3.5ns or less (17.5ns or less : 2mV/div.) - CH1 output : 20mV/div. into 50з / 50Hz to 30MHz(-3dB) - Polarity inversion : CH2 only - Signal delay : delay cable installed |
HORIZONTAL
DEFLECTION |
- Sweep mode : A, A int B, B, B triggered, X-Y
- Time base A : 0.1Я/div. to 0.5s/div. in 21 calibrated steps of 1-2-5 sequence uncalibrated continuous control between steps at least 1:2.5 - Hold-off time on time base A : variable with the hold-off control - Time base B : 0.1Я/div. to 10Я/div. in 7 calibrated steps of 1-2-5 sequence - Delay sweep on time base B: 1div. or less / 10 div. or more - Sweep magnification : 10 times (max. sweep rate : 10ns/div.) - Accuracy : ±3%, ±5%(1:10 probe) |
TRIGGER
SYSTEM |
- Accuracy :
- Modes : AUTO, NORM, TV-V, TV-H - Source : INT, LINE, EXT - Coupling : AC - Slope : + or - - Sensitivity and frequency in AUTO, NORM 30Hz -10MHz : 0.48div. in INT / 200mVp-p in EXT - Sensitivity and frequency in AUTO, NORM 10MHz -100MHz : 1.5div. in INT / 600mVp-p in EXT - Sensitivity and frequency in ALT trigger 30Hz -10MHz : 1.5div. in INT - Sensitivity and frequency in ALT trigger 10MHz -10MHz : 1.5div. in INT - Maximum input voltage : 250V (DC + AC peak) |
X-Y OPERATION |
- Sensitivity : same as vertical deflection for both X-axis(CH1) except accuracy
±5% in X-axis - Frequency and bandwidth : DC to 2MHz (DC coupling) / 10Hz to 2MHz (AC coupling) - X-Y phase difference : 3°or less as DC to 50kHz |
CALIBRATOR |
- Probe adjustment : approx. 1kHz frequency, 0.5V(±3%) square wave with 50%
duty ratio |
POWER SUPPLY |
- Line voltage range : 100V(90-110V) with 250V 2A fuse, 120V(108-132V) with
250V 2A fuse, 220V(198-242V) with 250V 1A fuse or 230V(216-250V) with 250V 1A fuse - Line frequency : 50/60Hz - Power consumption : approx. 60WOTHERSz |
PHYSICALCHARACTERISTICS |
- Weight : 9.6kg
- Dimension : 320mm(W) X 140mm(H) X 430mm(L) |
OTHERS
|
- Accessories including : Operation manual, Spare fuse, Power cord
- Optional accessories (sold separately) : Probe |