试验探针 P11.24
产品简介
试验探针/UL试验探针,用于测试电器产品的结构和外壳是否有良好防触电保护,以保证使用时不与带电部件发生意外接触。产品概述:符合UL1278图10.3标准要求。
产品详细信息
试验探针/UL试验探针/Triangle probe
试验探针用于测试电器产品的结构和外壳是否有良好防触电保护,以保证使用时不与带电部件发生意外接触。
产品概述:符合UL1278图10.3标准要求。
10.1.3 The acceptability of a guard is judged with respect to its general serviceability and with respect to
the shape and size or both of the openings in it, in conjunction with the distance of the guard from the
heating element and the other high-temperature parts mentioned in 10.1.1. Except as noted in 10.1.5, an
opening in a guard is considered to be acceptable if, with the heater in any intended operating position,
the following conditions are met:
b) The shape and size of an opening which permits the vertically downward entrance of a bar
probe 1/2 inch (12.7 mm) wide and 1/16 inch (1.6 mm) thick, see Figure 10.2, are such that a
triangle probe 1/16 inch thick and in the form of an isosceles triangle having a base of 2-3/4
inches and an altitude of 5-1/2 inches, see Figure 10.3, is prevented from touching the heating
element and the other high-temperature parts when the triangle probe is inserted, apex first, in
any manner. The testing of an opening with the triangle probe applies also where the vertically
downward insertion of the bar is prevented by the construction of the guard, the use of an
additional barrier, or both, unless the vertically applied bar tends to be deflected outward – that
is, away from the guard.
试验探针用于测试电器产品的结构和外壳是否有良好防触电保护,以保证使用时不与带电部件发生意外接触。
产品概述:符合UL1278图10.3标准要求。
10.1.3 The acceptability of a guard is judged with respect to its general serviceability and with respect to
the shape and size or both of the openings in it, in conjunction with the distance of the guard from the
heating element and the other high-temperature parts mentioned in 10.1.1. Except as noted in 10.1.5, an
opening in a guard is considered to be acceptable if, with the heater in any intended operating position,
the following conditions are met:
b) The shape and size of an opening which permits the vertically downward entrance of a bar
probe 1/2 inch (12.7 mm) wide and 1/16 inch (1.6 mm) thick, see Figure 10.2, are such that a
triangle probe 1/16 inch thick and in the form of an isosceles triangle having a base of 2-3/4
inches and an altitude of 5-1/2 inches, see Figure 10.3, is prevented from touching the heating
element and the other high-temperature parts when the triangle probe is inserted, apex first, in
any manner. The testing of an opening with the triangle probe applies also where the vertically
downward insertion of the bar is prevented by the construction of the guard, the use of an
additional barrier, or both, unless the vertically applied bar tends to be deflected outward – that
is, away from the guard.