DC OUTPUT |
| CH1, CH2 | CH3 | |
Voltage | |
Current | |
Tracking Series Voltage | |
Tracking Parallel Current | |
CONSTANT VOLTAGE OPERATION |
Line Regulation | ≦0.01% + 3mV |
Load Regulation | ≦0.01% + 3mV (rating current≦3A) ≦0.02% + 5mV (rating current >3A) |
Ripple & Noise | ≦1mVrms 5Hz ~ 1MHz |
Recovery Time | ≦100μS ( 50% Load change, Minimum load 0.5A ) |
Temp. Coefficient | ≦300ppm/°C |
Output Range | 0 to rating voltage continously adjustable |
CONSTANT CURRENT OPERATION |
Line Regulation | ≦0.2% + 3mA |
Load Regulation | ≦0.2% + 3mA |
Ripple Current | ≦3mArms |
Output Range | 0 to rating current continously adjustable |
TRACKING OPERATION |
Parallel Regulation | Line Regulation≦ 0.01% + 3mV Load Regulation≦ 0.01% + 3mV (rating current≦3A) Load Regulation≦0.02% + 5mV (rating current >3A) |
Series Regulation | Line Regulation≦0.01% + 5mV Load Regulation≦300mV Tracking Error≦ 0.5% ± 10mV (10 ~ 30V no load) (with load added≦300mV) Tracking Error≦0.5% ± 30mV (0 ~ 9.99V no load) (with load added≦300mV) |
CH3 OPERATION |
Output Voltage | 2.5V/3.3V/5V ±8% |
Output Current | 3A |
Line Regulation (25±5°C) | ≦5mV |
Load Regulation (25±5°C) | ≦15mV |
Ripple & Noise | ≦2mVrms |
METER |
Display | Voltage: 2 3/4 digits 0.4" LED display Current: 2 3/4 digits 0.4" LED display |
Voltage Resolution | 100 mV |
Current Resolution | 10 mA |
Program Accuracy (25±5°C) | Voltage: ±(0.05% of RDG + 2 digits) Current: ±(0.05% of RDG + 2 digits) |
Readback Accuracy (25±5°C) | Voltage: ±(0.05% of RDG + 2 digits) Current: ±(0.05% of RDG + 2 digits) |
KEY LOCK |
| Yes |
MEMORY SAVE/RECALL |
| 4 sets |
POWER SOURCE | |
| AC 100V/120V/220V/230V ±10%, 50/60Hz |
ACCESSORIES |
| User manual x 1 Power cord x 1 European test lead GTL-203 x 1, GTL-204 x 2 |
DIMENSIONS & WEIGHT |
| 210(W) x 130(H) x 265(D)mm, Approx. 7kg |