多孔同轴电极 Multi-well Coaxial Electrodes
产品简介
同轴电极用于对生长在96孔板里的贴壁细胞或者悬浮细胞进行电穿孔
产品详细信息
同轴电极用于对生长在96孔板里的贴壁细胞或者悬浮细胞进行电穿孔
共轴电极设计用于对96孔板里的细胞进行电穿孔。电极组建由但共轴电极或者多个共轴电极两种。共轴电极为盘状,产**散的电穿孔场,可以上至0.3毫升。
共轴电极用于对生长在96孔板里的贴壁细胞或者悬浮细胞进行电穿孔。只需简单加入感兴趣的外援分子,混合进行电穿孔。共轴电极很容易清洗,有一个干燥盒附件。,用肥皂及清水进行洗涤,用酒精**
The Coaxial Electrodes are designed to be used for electroporation of cells in a 96-well plate. The electrode assembly is available as a Single-Coaxial Electrode* or Multi-Coaxial Electrode (8-microwell channel electrode assembly). The Coaxial Electrodes are circular shape and produce divergent fields for electroporation of up to 0.3 ml. The Coaxial Electrodes can be used with all BTX electroporation systems.
* Single Electrode not shown
Applications
The Coaxial Electrodes have been used for electroporation of adherent cells grown in the 96-well plate or suspension cells1. Simply add the exogenous molecule of interest, mix and electroporate. The Coaxial Electrode is easy to clean and it includes a drying chamber. Wash with soap and water and sterilize with alcohol.
Ordering Information
Model Description
491-1 *Single-Coaxial Electrode
Electroporates one well at a time
747 8 Well Coaxial Electrode - Includes Drying Chamber Electroporates 8 wells at a time
840 96 Well Coaxial Electrode - Includes Drying Chamber Electroporates 96 wells at a time
References
METHODS IN MOLECULAR AND CELLULAR BIOLOGY, vol. 5: 353-362 (1995) "Electroporation of COS-7 Cells With Transient Expression Vectors in 96 Well Microplates by Single, 8, and 96 Well Coaxial Electrodes"; Takacs L., M.D., Ph.D.
BTX protocol numbers PR0228 & PR0229.
共轴电极设计用于对96孔板里的细胞进行电穿孔。电极组建由但共轴电极或者多个共轴电极两种。共轴电极为盘状,产**散的电穿孔场,可以上至0.3毫升。
共轴电极用于对生长在96孔板里的贴壁细胞或者悬浮细胞进行电穿孔。只需简单加入感兴趣的外援分子,混合进行电穿孔。共轴电极很容易清洗,有一个干燥盒附件。,用肥皂及清水进行洗涤,用酒精**
The Coaxial Electrodes are designed to be used for electroporation of cells in a 96-well plate. The electrode assembly is available as a Single-Coaxial Electrode* or Multi-Coaxial Electrode (8-microwell channel electrode assembly). The Coaxial Electrodes are circular shape and produce divergent fields for electroporation of up to 0.3 ml. The Coaxial Electrodes can be used with all BTX electroporation systems.
* Single Electrode not shown
Applications
The Coaxial Electrodes have been used for electroporation of adherent cells grown in the 96-well plate or suspension cells1. Simply add the exogenous molecule of interest, mix and electroporate. The Coaxial Electrode is easy to clean and it includes a drying chamber. Wash with soap and water and sterilize with alcohol.
Ordering Information
Model Description
491-1 *Single-Coaxial Electrode
Electroporates one well at a time
747 8 Well Coaxial Electrode - Includes Drying Chamber Electroporates 8 wells at a time
840 96 Well Coaxial Electrode - Includes Drying Chamber Electroporates 96 wells at a time
References
METHODS IN MOLECULAR AND CELLULAR BIOLOGY, vol. 5: 353-362 (1995) "Electroporation of COS-7 Cells With Transient Expression Vectors in 96 Well Microplates by Single, 8, and 96 Well Coaxial Electrodes"; Takacs L., M.D., Ph.D.
BTX protocol numbers PR0228 & PR0229.