- 入驻时间: 2006-07-26
- 联系人:叶先生
- 电话:0756-3895880
-
联系时,请说明易展网看到的
- Email:yetao@combine-inst.com
PS76 系列压力开关
坚固的圆柱型压力开关
概述/设计原理:
特性...
- 15 到 1750 psi (1到 121 bar)
- 侧装 DIN连接
- 顶装电气连接
- 有DPDT型可选
- 在低温极限下设定点变化极小
PS76系列压力开关基于多功能微动开关设计,适用于OEM客户的高压应用,拥有已经证实的PS75型号产品的全部性能,同时具备Kapton®的低温能力.
性能参数: | ||
接液端口 |
隔膜: Kapton (polyimide) |
|
工作温度 |
see table below |
|
|
see table below |
|
电气端子 |
DIN 43650A, IP65 Terminals |
|
耐压 |
4500 psi (517 bar) except Range 10: 500 psi (35 bar) |
|
Burst Pressure | 6000 psi (414 bar) | |
Approvals |
CE, UL Approved units available, consult factory |
|
重量 |
Steel: 0.6 lbs (0.27 kg) |
Recommended Operating Temperature Limits* | |||
隔膜Material |
-A, -B, -C Circuit without -RD |
-AA, -BB, -CC Circuit or -RD |
|
Teflon Coated Kapton® |
-40°F to 185°F (-40°C to 85°C) |
-40°F to 250°F (-40°C to 121°C) |
Switch Ratings | |||
Electrical Switch Ratings |
AC |
DC |
|
-A, -B, -C without -G |
5 amps @ 125/250 Volts |
5 amps resistive, 3 amps inductive @28 Volts |
|
-A, -B, -C with -G |
1 amp @ 125 Volts |
1 amp resistve, 0.5 amps inductive @ 28 Volts |
|
-AA, -BB, -CC, without -G |
2 switches rated 5 amps @ 125/250 Volts |
2 switches rated 5 amps resistive, 3 amps inductive @ 28 Volts |
|
-AA, -BB, -CC with -G |
2 switches rated 1 amp @ 125/250 Volts |
2 switches rated 1 amp resistive, 0.5 amps inductive @ 28 Volts |
Repeatability / Deadband | |||
Pressure Range Code |
Pressure Range |
Repeatability |
Average Deadband* |
-A, -B, -C Circuits |
|||
10 |
15 - 75 psi (1-5.2 bar) |
± 2.5 psi (0.17 bar) + 3% of setting |
5 psig (0.34 bar) +11% of setting |
20 |
50 - 150 psi (3.5-10 bar) |
± 6 psi (0.41 bar) + 3% of setting |
15 psig (1.03 bar) + 14% of setting |
30 |
150 - 650 psi (10.3-44.8 bar) |
± 15 psi (1.03 bar) + 3% of setting |
25 psi (1.72 bar) + 15% of setting |
40 |
500 - 1750 psi (34.5-121 bar) |
±25 psi (17.2 bar) + 3% of setting |
55 psi (3.79 bar) + 16% of setting |
-AA, -BB, -CC Circuits** |
|||
10 |
15 - 75 psi (1-5.2 bar) |
± 3.5 psi (0.24 bar) + 4% of setting |
4 psig (0.28 bar) + 9% of setting |
20 |
50 - 150 psi (3.5-10.3 bar) |
± 9 psi (0.62 bar) + 4% of setting |
13 psig (0.90 bar) + 11% of setting |
30 |
150 - 650 psi (10.3-44.8 bar) |
± 22 psi (1.51 bar) + 4% of setting |
21 psi (17.2 bar) + 12% of setting |
40 |
500 - 1750 psi (34.5-121 bar) |
± 35 psi (2.41 bar) + 4% of setting |
45 psi (3.10 bar) + 13% of setting |
* In certain applications, deadband can be tailored and controlled to customer specifications. Consult factory for details.
** Operation of both switches in most cases will not be simultaneously, but will occur within the specifications listed. Deadband figures already reflect the improvement from the -RD option which is automatically included in the -AA, -BB, and -CC circuits.