Electric security:
- measurement category: CAT III 600V acc. to EN 61010-1:2004
- protection class acc. to EN 60529: IP40
Other technical data:
- power supply: 9V battery type 6LR61
- display: 6600 counts, backlit LCD
- continuity test: threshold 40Ω; test current < 0,5mA
- diode test: test current of 0,3mA, typical open circuit voltage < 3V DC, typical
- low battery indication: BAT displayed
- over range indication: 0L displayed
- sampling rate: 2 times per second
- INRUSH: integration time 100ms
- temperature sensor: type K thermocouple
- input impedance: 10MΩ (V DC and V AC)
- AC bandwidth: 50...400Hz (A AC and V AC)
- auto power OFF: approx. 25 min.
- dimensions: 229 x 80 x 49 mm
- weight: 303 g
- accordance with following standards: EN 61010-1:2004, EN 61010-2-032
- quality standard: ISO 9001
Rated operational conditions:
- internal clamp diameters: d1=36mm/d2=52mm
- operating temperature: +5...+40°C
- storage temperature: -20...+60°C
- operating humidity: max 80% up to 31°C decreasing linearly to 50% at 40°C
- storage humidity: <80%
- operating altitude: max 2000 m
AC/DC current measurement (TRUE RMS)
Range |
Resolution |
Accuracy
(DC) |
Accuracy
(AC) |
0...659,9A |
0,1A |
±(2,5% m.v. +5 dgt) |
±(2,5% m.v + 8 dgt)
for f=50...60Hz
|
660...1000A |
1A |
±(2,8% m.v. +8 dgt) |
±(2,8% m.v. + 8 dgt)
for f=50...60Hz
|
DC voltage measurement
Range |
Resolution |
Accuracy
|
0...6,599V |
0,001V |
±(1,5% m.v. + 3 dgt)
|
6,60...65,99V |
0,01V |
66,0...1000,0V |
0,1V |
AC voltage measurement (TRUE RMS)
Range |
Resolution |
Accuracy
|
0...6,599V |
0,001V |
±(1,8% m.v. + 5 dgt)
for f=50...60Hz
|
6,60...65,99V |
0,01V |
66,0...1000,0V |
0,1V |
Resistance measurement
Range |
Resolution |
Accuracy |
0,0...659,9Ω |
0,1Ω |
±(1,0% m.v. + 4 dgt) |
0,660...6,599kΩ |
0,001kΩ |
±(1,5% m.v. + 2 dgt) |
6,60...65,99kΩ |
0,01kΩ |
66,0...659,9kΩ |
0,1kΩ |
0,660...6,599MΩ |
0,001MΩ |
±(2,5% m.v. + 3 dgt) |
6,60...66,00MΩ |
0,01MΩ |
±(3,5% m.v. + 5 dgt) |
Frequency measurement
Range |
Resolution |
Accuracy |
30,0...999,9Hz |
0,1Hz |
±(1.2% m.v. + 2 dgt)
sensitivity:30...5kHz:10Vrms min.
5kHz...15kHz:40Vrms min.
for 20%...80% duty cycle
|
1,000...9,999kHz |
0,001kHz |
10,00...15,00kHz |
0,01kHz |
Temperature measurement
Range |
Resolution |
Accuracy |
-20...760°C |
0,1°C |
±(3,0% m.v. + 5°C)
|
-4...1400°F |
0,1°F |
±(3,0% m.v. + 9°F) |
Duty cycle measurement
Range |
Resolution |
Accuracy |
10,0...94,9% |
0,1% |
±(1,2% m.v. + 2 dgt) |
• pulse width: 100μs...100ms,
• frequency range: 30Hz...5kHz,
• sensitivity: 30Hz...5kHz: 10Vrms, 5kHz...15kHz: 40Vrms.
„m.v.”- measured value