> 法国多寿dosatron水力比例配比泵D15F2

产品资料

法国多寿dosatron水力比例配比泵D15F2

法国多寿dosatron水力比例配比泵D15F2
  • 如果您对该产品感兴趣的话,可以
  • 产品名称:法国多寿dosatron水力比例配比泵D15F2
  • 产品型号:D15F2
  • 产品展商:dosatron
  • 产品文档:无相关文档
简单介绍
法国多寿dosatron水力比例配比泵中带F的型号都为固定比例添加。专为某一特定药液添加提供便利。固定比例省去了调节的繁琐,只要控制运行水量就能使添加量一目了然。并且固定的比例使dosatron更经久耐用。
产品描述
运行原理
Dosarton注入泵直接安装在供水管路上,依靠经过的水流作为运行动力。水驱动Dosarton注入泵运行,按照需要的比例将浓缩液从容器中直接吸入并注入到水中。在Dosarton泵内,浓缩液与水充分混合,水压将稀释混合液输送到下游管网。不管供水管路上的水量和压力发生什么变化,所注入浓缩液的剂量与进入Dosarton泵的水量始终成比例。


D25RE2主要规格参数    
注入比例调节范围                                 2%(1:50)
运行时水流量范围                                 10升/小时~1.5立方米/小时
运行水压                                                 0.5~5BAR
浓缩液(母液)注入流量                     0.4升/小时~30升/小时

法国多寿dosatron水力比例配比泵中带F的型号都为固定比例添加。专为某一特定药液添加提供便利。固定比例省去了调节的繁琐,只要控制运行水量就能使添加量一目了然。并且固定的比例使dosatron更经久耐用。

 
 

 

 


 

dosatron常见问题问答

Having installed a new Dosatron, it does not work. Why not?
- Is the unit installed the right way round, according to arrow?
- The BYPASS must be in the ON position.
- Was the priming (of the emply unit) carried out slowly?


When starting the unit, it 'clicks' but no product is sucked up.
- Check that the suction hose is submerged in the concentrate.
- Make sure the priming procedure is carried out correctly.
- Check that air is not being sucked in at the suction hose connection.

The unit does not suck up the correct quantity of chemical.
- How was the concentration of chemical in the water measured?
- DOSATRON dosing principle:1 volume of chemical for 100 volumes of water by setting at 1% (1:100).
- When were the dosing seals last changed?
- Excessive flow, causing cavitation. (A temporary vacuum being formed in the doser body by each stroke of the plunger. May also be caused by viscous products - contact your dealer).

The adjustment of the dosing rate cannot be done easily.
- Has the pressure in the installation been reduced to zero before adjusting?
- Has the blocking ring of the adjusting nut been released (one turn approximately)?

The unit is over-dosing.
- This is certainly caused by chemical syphoning upstream or downstream of the unit

The product container is filling up with water.
- The problem is due to the suction valve, which is either stuck open, or its seal is missing or worn.

The unit does not work at low flow.
- Is the filtration functioning correctly?
- Is the unit working with water temperatures over 40 ° C?

The unit has a crack.
- Was the unit protected from frost?
- Was it subject to water hammer?
- Was it subject to chemical attack?

The unit, installed behind glass, has turned white.
- This is due to the sun's UV rays. There is no mechanical effect on the unit's operation.

The unit has developed white spots.
- This is the result of chemical attack
产品留言
标题
联系人
联系电话
内容
验证码
点击换一张
注:1.可以使用快捷键Alt+S或Ctrl+Enter发送信息!
2.如有必要,请您留下您的详细联系方式!
  • 温馨提示:为规避购买风险,建议您在购买前务必确认供应商资质与产品质量。
  • 免责申明:以上内容为注册会员自行发布,若信息的真实性、合法性存在争议,平台将会监督协助处理,欢迎举报
产品留言
标题
内容
联系人
联系电话
电子邮件
公司名称
联系地址
验证码
点击换一张
注:1.可以使用快捷键Alt+S或Ctrl+Enter发送信息!
2.如有必要,请您留下您的详细联系方式!

苏公网安备 32028102000820号