企业信息
第7年
- 入驻时间: 2015-11-06
- 联系人:顾磊
- 电话:021-60514606
-
联系时,请说明易展网看到的
- Email:shybio@126.com
产品分类
产品详情
简单介绍:
降钙素基因相关肽(CGRP)检测试剂盒用于测定血清,血浆及相关液体等样本,例如适合检测包括血清、血浆、尿液、胸腹水、灌洗液、细胞培养上清、组织匀浆等本标本。产品种类齐全、质量可靠、价格优惠、灵敏度高、效果稳定、易保存、操作简单。
详情介绍:
降钙素基因相关肽(CGRP)检测试剂盒CLIA Kit for Calcitonin Gene Related Peptide (CGRP)
FOR IN VITRO AND RESEARCH USE ONLY, NOT FOR USE IN CLINICAL DIAGNOSTIC PROCEDURES!
Organism species | Mus musculus (Mouse) |
Product No. | YBA876Mu |
Sample type | Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids |
Format | 96T |
Assay length | 2.5 hours |
Detection range | 7.81-2000pg/mL The standard curve concentrations used for the CLIA’s were 2000pg/mL, 500pg/mL, 125pg/mL, 31.25pg/mL, 7.81pg/mL |
Sensitivity | The minimum detectable dose of this kit is typically less than 2.77pg/mL. |
降钙素基因相关肽(CGRP)检测试剂盒Specificity
This assay has high sensitivity and excellent specificity for detection of Calcitonin Gene Related Peptide (CGRP).
No significant cross-reactivity or interference between Calcitonin Gene Related Peptide (CGRP) and analogues was observed.
No significant cross-reactivity or interference between Calcitonin Gene Related Peptide (CGRP) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Calcitonin Gene Related Peptide (CGRP) and the recovery rates were calculated by comparing the measured value to the expected amount of Calcitonin Gene Related Peptide (CGRP) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 97-104 | 101 |
EDTA plasma(n=5) | 80-103 | 91 |
heparin plasma(n=5) | 82-92 | 89 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Calcitonin Gene Related Peptide (CGRP) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Calcitonin Gene Related Peptide (CGRP) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Calcitonin Gene Related Peptide (CGRP) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
降钙素基因相关肽(CGRP)检测试剂盒Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Calcitonin Gene Related Peptide (CGRP) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 88-102% | 85-96% | 96-103% | 94-103% |
EDTA plasma(n=5) | 80-98% | 95-103% | 80-103% | 79-102% |
heparin plasma(n=5) | 79-94% | 80-102% | 88-95% | 79-101% |
降钙素基因相关肽(CGRP)检测试剂盒Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
Pre-coated, ready to use 96-well strip plate | 1 | Plate sealer for 96 wells | 4 |
Standard | 2 | Standard Diluent | 1×20mL |
Detection Reagent A | 1×120µL | Assay Diluent A | 1×12mL |
Detection Reagent B | 1×120µL | Assay Diluent B | 1×12mL |
Substrate A | 1×10mL | Substrate B | 1×2mL |
Wash Buffer (30 × concentrate) | 1×20mL | Instruction manual | 1 |
降钙素基因相关肽(CGRP)检测试剂盒Assay procedure summary
1. Prepare all reagents, samples and standards;
2. Add 50µL standard or sample to each well.
And then add 50µL prepared Detection Reagent A immediately.
Shake and mix. Incubate 1 hour at 37oC;
3. Aspirate and wash 3 times;
4. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37oC;
5. Aspirate and wash 5 times;
6. Add 100µL Substrate Solution. Incubate 10 minutes at 37oC;
7. Read RLU value immediately.
2. Add 50µL standard or sample to each well.
And then add 50µL prepared Detection Reagent A immediately.
Shake and mix. Incubate 1 hour at 37oC;
3. Aspirate and wash 3 times;
4. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37oC;
5. Aspirate and wash 5 times;
6. Add 100µL Substrate Solution. Incubate 10 minutes at 37oC;
7. Read RLU value immediately.
降钙素基因相关肽(CGRP)检测试剂盒Test principle
The microtiter plate provided in this kit has been pre-coated with a monoclonal antigen. A competitive inhibition reaction is launched between biotin labeled Calcitonin Gene Related Peptide (CGRP) and unlabeled Calcitonin Gene Related Peptide (CGRP) (Standards or samples) with the pre-coated secondary antibody. After incubation the unbound conjugate is washed off. Next, avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. The amount of bound HRP conjugate is reverse proportional to the concentration of Calcitonin Gene Related Peptide (CGRP) in the sample. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is reverse proportional to the Calcitonin Gene Related Peptide (CGRP) level in the sample or standard.