機種型號
|
CP-268-1
|
CP-268-2
|
CP-268-5
|
CP-268-PS
|
Voltage(V)
|
Ranges (Auto or Manual)(9 range)
|
30V 60V 150V 300V 600V RMS
|
1.5V 3V 6V 15V 30V 60V 150V 300V 600V RMS
|
Display Resolution
|
5 digits
|
Operating Principle
|
Digital Calculation True RMS
|
Crest Factor
|
Up to 1.7(at FULL SCALING)台湾擎宏功率表CP-268-1
|
Frequency Range
|
10Hz to 1000Hz
|
Accuracy
(23℃ ± 5℃)
|
10 to 20Hz
|
±1% reading ± 1% range ± 2C
|
20 to 30Hz
|
±0.5% reading ± 0.5% range ± 2C
|
30 to 45Hz
|
±0.2% reading ± 0.2% range ± 2C
|
45 to 66Hz
|
±0.1% reading ± 0.1% range ± 2C
|
66 to 550Hz
|
±0.2% reading ± 0.2%range ± 0.1% / 100Hz
|
550 to 1000Hz
|
±0.2% reading ± 0.5%range ± 0.2% / 100Hz
|
Maximum Input
|
Continuous
|
Continuous 600V RMS / 1000Vpk
|
Input impedance
|
2 MΩ and 10 pF on all ranges
|
Effective input range
|
20% to 120% of the range
|
Current (A)
|
Ranges (Auto or Manual)(15 ranges)
|
100mA 200mA 500mA 1A 2A
5A 10A 20A RMS
|
1mA 2mA 5mA 10mA
20mA 50mA 100mA
200mA 500mA 1A 2A
5A 10A 20A RMS
|
1mA 2mA 5mA 10mA
20mA 50mA 100mA
200mA 500mA 1A 2A
5A 10A 20A 50A RMS
|
1mA 2mA 5mA 10mA
20mA 50mA 100mA
200mA 500mA 1A 2A
5A 10A 20A RMS
|
Display Resolution
|
5 digits
|
Operating Principle
|
Digital Calculation True RMS
|
Crest Factor
|
Up to 2 (at FULL SCALING)台湾擎宏功率表CP-268-1
|
Up to 4 (at FULL SCALING)
|
Frequency Range
|
10Hz to 1000Hz
|
Accuracy
(23℃± 5℃)
|
Range
|
50A ~ 100mA
|
50mA ~ 1mA
|
10 to 20H
|
±1% reading ± 1% range ± 2C
|
±2% reading ± 2% range ± 2C
|
20 to 30Hz
|
±0.5% reading ± 0.5% range ± 2C
|
±1% reading ±1% range ± 2C
|
30 to 45Hz
|
±0.2% reading ± 0.2% range ± 2C
|
±0.4% reading ± 0.4% range ± 2C
|
45 to 66Hz
|
±0.1% reading ± 0.1% range ± 2C
|
±0.2% reading ± 0.2% range ± 2C
|
66 to 550Hz
|
±0.2% reading ± 0.2%range ± 0.1% / 100Hz
|
±0.4% reading ± 0.4%range ± 0.2% / 100Hz
|
550 to 1000Hz
|
±0.2% reading ± 0.3%range ± 0.2% / 100Hz
|
±0.4% reading ± 0.6%range ± 0.4% / 100Hz
|
Maximum Input
|
Continuous
|
20A RMS / 40Apk
|
20A RMS / 40Apk
|
50A RMS / 100Apk
|
20A RMS / 80Apk
|
Input impedance
|
All ranges ≦ 2 mΩ
|
Effective input range
|
10% to 110% of the range
|
Power(W)
|
Ranges (Auto or Manual)
|
3W to 12kW
40 ranges
|
1.5mW to 12kW
126 ranges
|
1.5mW to 30kW
135 ranges
|
1.5mW to 12kW
126 ranges
|
Display Resolution
|
5 digits
|
Operating principle
|
Digital Calculation True Watt
|
Frequency Range
|
10Hz to 1000Hz
|
Accuracy
(23℃ +/- 5℃)
|
Range
|
50A ~ 100mA
|
50mA ~ 1mA
|
10 to 20Hz
|
±1% reading ± 1% range ± 2C
|
±2% reading ± 2% range ± 2C
|
20 to 30Hz
|
±0.5% reading ± 0.5% range ± 2C
|
±1% reading ±1% range ± 2C
|
30 to 45Hz
|
±0.2% reading ± 0.2% range ± 2C
|
±0.4% reading ± 0.4% range ± 2C
|
45 to 66Hz
|
±0.2% reading ± 0.2% range ± 2C
|
±0.4% reading ± 0.4% range ± 2C
|
66 to 550Hz
|
±0.2% reading ± 0.2%range ± 0.1% / 100Hz
|
±0.4% reading ± 0.4%range ± 0.2% / 100Hz
|
550 to 1000Hz
|
±0.2% reading ± 0.5%range ± 0.2% / 100Hz
|
±0.4% reading ± 1%range ± 0.4% / 100Hz
|
Effective input range
|
2% to 110% of the range (at 47 to 63Hz)
5% to 110% of the range (at all range)台湾擎宏功率表CP-268-1
|
Frequency(Hz)
|
Display Resolution
|
5 digits
|
Maximum resolution
|
.001Hz of 10.000Hz to 99.999Hz0
0.01Hz of 100.00Hz to 999.99Hz
0.1Hz of 1000.0Hz to 2000.0Hz
|
Operating Principle
|
Reciprocal Counting method 台湾擎宏功率表CP-268-1
|
Accuracy(23℃ ± 5℃)
|
±0.02% ± 1C 台湾擎宏功率表CP-268-1
|
Measuring Input
|
Voltage
|
Effective input range
|
10% to 100% of the voltage range
|
Measuring Range
|
10 Hz to 2kHz
|