下载文件详细资料
  文件名称:  ISO 105-G03
  公司名称:  广东宏展科技有限公司
  下载次数:   960
  文件详细说明:
 
本页面标准信息均来源于网络收集,或由参与标准制定的供应商提供,只作为参考使用,为确保测试结果的准确性、节省您的时间,如需ISO 105-G03测试标准标准详细信息或ISO 105-G03测试标准具体测试方法,欢迎致电与我们技术人员联系或给我们留言,我们将为您相关的技术支持。

ISO 105-G03简介

ISO 105-G03是关于耐大气臭氧色牢度的测试标准。

ISO 105-G03描述了关于在湿度不超过65%的室内温度条件下,或者高温条件中湿度80%以上环境中各类纺织用品耐大气臭氧色牢度的测试方法。现行最新标准版本为ISO 105-G03-2015。

以下为部分英文标准原文,出于版权保护,如需ISO 105-G03标准全文或ISO 105-G03中文版本标准,请垂询客服人员。

1 Scope

This part of IS0 105 specifies a method for determining the resistance of the colour of textiles of all kinds and in all forms to the action of ozone in the atmosphere, both at ambient room temperatures with relative humidities not exceeding 65 % and at elevated temperatures with relative humidities above 80 %.

NOTE l If a sample shows sensitivity to this test, it should also be tested for sensitivity to the tests specified in lS0 105-G01 (colour fastness to nitrogen oxides) and JS0 105-G02 {colour fastness to burnt-gas fumes).

2 Normative references

The following standards contain provisions which, through reference in this text, constitute provisions of this part of IS0 105. At the time of publication, the editions indicated were valid. All standards are subject to revision, and parties to agreements based on this

part of IS0 105 are encouraged to investigate the possibility of applying the most recent editions of the standards indicated below. Members of IEC and ISO maintain registers of currently valid International Standards.

IS0 105-A01:1989, Textiles - Tests for colour fastness - Part AO1: General principles of testing.

IS0 105-A02:1993, Textiles - Tests for colour fastness - Part A02: Grey scale for assessing change in colour.

IS0 105-F:1985, Textiles - Tests for colour fastness - Part F: Standard adjacent fabrics.

3 Principle

3,1 A specimen and a swatch of test-control fabric are simultaneously exposed to ozone, in an atmosphere at ambient room temperature and a relative humidity not exceeding 65 %, until the test control shows a colour change corresponding to that of a standard of fading. This exposure period constitutes one cycle. The cycles are repeated until the specimen shows a definite colour change or for a prescribed number of cycles.

3,2 A specimen and a swatch of test-control fabric are simultaneously exposed to ozone in an atmosphere which is maintained at (85 ± 5) % relative humidity and a temperature of 40 ℃C + 5 ℃until the test control shows a colour change corresponding to that of a standard of fading. The cycle is repeated until the specimen shows a definite colour change or for a prescribed number of cycles.

NOTE 2 The fadding of dyes on certain fibres does not readilly take place at humidities below 80 %. The test at high humidity is therefore required to produce a colour change that predicts service fading under warm, humid conditions.

4 Apparatus and materials

4.1 0zone exposure chamber for ambient room temperatures and relative humidities not exceeding 65 % (see A.l).

4,2 0zone exposure chamber for elevated tem peratures and relative humidities above 80 % (see clause A.2).

4.3 Test-control fabric for relative humidities not exceeding 65 % (see annex B).

4.4 Standard of fading for relative humidities not exceeding 65 % (see annex B).

4.5 Test-control fabric for high humidities (see annex B).

4.6 Standard of fading for high humidity (see annex B).

4.7 Grey scale for assessing change in colour,complying with IS0 105-A02,

5 Test specimens

5.1 If the textile to be tested is fabric, use a specimen measurcng 60 mm x l00 mm.

5.2 If the textile to be tested is yarn, knit it into fabric and use a piece measuring 60 mm x 100 mm or wind it closely round a piece of cardboard measuring 60 mm x 100 mm to form a layer having only the thickness of the yarn,

5.3 lf the textile to be tested is loose fibre, comb and compress enough of it to form a sheet measuring 60 mm x 100 mm and sew the sheet on a piece of cotton adjacent fabric, complying with IS0 105-F, section F02, to support the fibre.

5.4 For subsequent colour comparison, the unexposed sample shall be kept in an airtight container away from light to avoid further shade change.

6 Procedure

6.1 At relative humidities not exceeding 65 %

6.1.1 Suspend each specimen and a swatch of the test-control fabric (4.3) in the exposure chamber (4.1) so that each piece hangs separately, The test shall be conducted with the chamber in a room in which the ambient air temperature is 18 °C to 28℃ and the relative humidlty does not exceed 65 %. Ozone shall be present in concentrations which produce one cycle if fading in 1.5 h t0 6 h of test.

6.1.2 Compare the colour of the control swatch with that of the standard of fading (4.4) periodically in day light ranging from average to slightly bluish North Sky light, or equivalent artificial light. When they match, the specimens have been exposed for one cycle and

each shall then be compared with a specimen of the untreated material.

6,1.3 Remove those specimens which exhibit a col our change at the end of one cycle, One cycle will generally produce a measurable colour change in samples which are ozone-sensitive.

6.1.4 Suspend a fresh swatch of the test-control fabric and continue exposure of any remaining specimens for a second cycle.

6.1.5 Run additional similar cycles as necessary.

6.1.6 At the end of each cycle, cmmediately compare those specimens which are removed from the exposure chamber with the preserved original samples from which they were drawn.

6.1.7 Assess the change in colour of the specimens,after any specified number of cycles, with the grey scale (4,7).

6.2 At high relative humidity

6.2.1 Suspend each specimen and a piece of the test-control fabric (4.5) in the exposure chamber (4.2) which is maintained at (85 ± 5) % relative humidityand a temperature of 40 °C ± 5 °C. Ozone shall be present in concentrations ranging from 10 pphm to 35 pphm, which should produce one cycle of fading in 6 h t0 24 h of test,

6.2.2 Compare the colour of the control swatch with that of the standard of fading (4.6) periodically in daylight ranging from average to slightly bluish North Sky light, or equivalent artificial light. When they match,the specimens have been exposed for one cycle and each shall then be compared with a specimen of the untreated material.

6.2.3 Remove those specimens which exhibit a colour change at the end of one cycle. One cycle will generally produce a measurable colour change in samples which are ozone-sensitive.

6,2.4 Suspend a fresh wwatch of the control sample and continue exposure of any remaining specimens for a second cycle.

6.2.5 Run additional similar cycles as necessary

6.2.6 At the end of each cycle, immediately com pare those specimens which are removed from the exposure chamber with the preserved original samples from which they were drawn.

6.2.7 Assess the change in colour of the specimens, after any specified number of cycles, with the grey scale (4.7).

7 Test report

The test report shall include the following particulars:

a) the number and date of publicatlon of this part of IS0 105, i.e. IS0 105-G03:1993;

b) all details necessary for the idantificatcon of the sample tested;

c} the numerical rating for the change in colour of each specimen;

d) the number ot cycles run and the temperature and relative humidity at which the test was performed.

文件下载(右键文件另存为)