- 入驻时间: 2006-07-03
- 联系人:陈先生
- 电话:13915600537
-
联系时,请说明易展网看到的
- Email:chen@cscyyb.com
常阳供应EP6122 Electro-Pneumatic Positioner
1. GENERAL
The EP 6000 Series Positioner,mounted on a pneumatic actuator,moves the actuator by receiving DC4~20mA signals from a controller.Also,the function of detecting and feeding back the actuator displacement provides accurate position in response to DC4~20mA signals.
The EP 6000 can be used with both single and double action on actuators.
2. 标准规格 2.STANDARD SPECIFICATIONS
2-1.编码 2-1.CODE NO.
6 |
|
|
|
|
系 列
Series |
6 |
0 |
0 |
0 |
|
|
|
|
|
|
防爆(防护)结构
Ex.enclosure |
1
2
3 |
|
|
|
|
|
|
耐压防爆型(隔爆型)d ExdlllBT6 Explosion proof type |
||
|
|
|
|
|
室外防水型(增安型)e ExellT6、lP55 Weather proof type |
|||||
|
|
|
|
|
本质**型(本安型)I ExiallCT6 Intrinsically safe explosion proof type |
|||||
反馈(动作)方式
Feedback style |
1
2 |
|
|
|
|
|
直行程执行机构用:标准型Linear:Feedback for standard lever |
|||
|
|
|
|
角行程(直连式回转轴)执行机构用:标准型Rotary:Feedback for lever |
||||||
作用型式Action type |
1
2 |
|
|
|
|
单动作型执行机构用(单作用)For single acting type |
||||
|
|
|
双动作型执行机构用(双作用)For double acting type |
|||||||
辅件Accessories |
21 |
|
|
带关联匹配 气压控制器Matched decompressor valve |
||||||
例:Example:
EP 6111: 表示 隔爆型、直行程、单作用、电气阀门定位器。
EP 6311: 表示 本安型、直行程、单作用、电气阀门定位器。
EP 6122: 表示 隔爆型、角行程、双作用、电气阀门定位器。
EP 6322: 表示 本安型、角行程、双作用、电气阀门定位器。
EP 6112: 表示 隔爆型、直行程、双作用、电气阀门定位器。
EP 6312: 表示 本安型、直行程、双作用、电气阀门定位器。
EP 6211: 表示 增安型、直行程、单作用、电气阀门定位器。
EP 6111-21:表示 隔爆型、直行程、单作用、电气阀门定位器带关联匹配组合 气压控制器。
2-2.技术参数 2-2.TECHNICAL DATA
系 列 Series |
EP 6000 |
输入信号 Input signal |
4~20mA DC The split range is possible by span
可进行分程控制 adjustment and zero adjustment
调整范围:4~12、12~20mA DC Adjustment range:4~12、12~20mA DC |
输入阻抗Input impedance |
250Ω±5%at25℃ |
输出特性Output Characteristic |
线性(标准型) Linear(standard) |
放大器 Relay |
单动作型执行机构和双动作型执行机构兼用,Non-bleeding type.
单动作正作用型放大器易变换成反作用型放 Single acting and double acting types
大器(输入信号增加,输出气压相应减小) are available. |
气源压力 Air supply |
0.14~0.7MPa(140~700KPa) |
输出压力 Output pressure |
0~0.7 MPa(0~700KPa) |
耗气量 Air consumption |
输出气压50%时的耗气量。 At output air pressure 50% 单动作型 Single acting type:5NI/min at 140 kpa air supply 双动作型 Double acting type:15NI/min at 400kpa air supply |
大处理容量Max.capacity |
输出侧气源放空时 Capacity when output is atmospheric venting.
单动作型 Single acting type:175NI/min at 140kpa air supply
双动作型 Double acting type:400NI/min at 400kpa air supply |
性 能Performance |
单动作型执行机构 For single acting actuator
直 线 性 Linearity∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙±1.0%of Full stroke
滞 后 Hysteresis∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙0.5%of Full stroke
灵 敏 度 Response level∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙0.1% of Full stroke
重 复 精 度 Repeatability∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙0.2% of Full stroke
气源压力变动误差 Supply pressure effect∙∙∙∙∙∙∙∙∙∙∙0.1%10Kpa
双动作型执行机构 For double acting actuator
直 线 性 Linearity∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙±1.5% of Full stroke
滞 后 Hysteresis∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙0.8% of Full stroke
灵 敏 度 Response level∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙0.2% of Full stroke
重 复 精 度 Repeatability∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙0.3% of Full stroke
气源压力变动误差 Supply pressure effect∙∙∙∙∙∙∙∙∙∙∙0.4%10Kpa
上述各数值是指在不连接阀门的情况下执行机构的性能。
The above data represent the performance of the positioner on an actuator without a valve. |
气源接口 Air connection |
Rc 1/4 NPT1/4 |
电气接口 Wiring connection |
G 1/2 NPT1/2 |
环境温度Ambient temperature |
标准型 Standard type -20~+80℃ |
湿度范围Ambient humidity range |
10~90%RH |
结构 |
|
附属机构Standard auxiliary |
自动-手动切换装置Auto-Manual switch |
外壳材料 Housing material |
铝合金Aluminum alloy |
表面 |
|
|
|
附加规格Optionalspecifications |
根据客户要求制作Available upon request |
电气接口 Wiring connection |
1/2NPT(室外防水型For waterproof only)
耐压填料式Packing cable gland(耐压防爆型For explosion proof only)
密封接头式Sealing fitting(耐压防爆型For explosion proof only) |
**栅Safety device |
齐纳**栅Zener barrier(Exia ll C) |
压力表刻度Pressure gauge |
Mpa、Kpa、Bar、Psi |
输出特性Output characteristic |
等百分比Equal percentage |
气源接口Air supply connection |
1/4NPT |
3、特点
①适用于小容量及大容量的执行机构
由于采用了载荷控制弹簧,选择相应的弹簧后就能获得适合于该执行的定位器。
②耗气量小
放大器的耗气量小、容量大。
③可以选择输出特性
由于反馈机械中有凸轮装置,因此可以选择标准特性以外的输出特性。
④各种反馈方式对应的型号
只要更换凸轮装置,就可以用于以下对应的执行机构。
*直行程执行机构:标准型∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ EP 6 1
*角行程执行机构:标准型∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ EP 6 2
⑤易变换成反作用放大器
单作用执行机构在需要反作用控制时,正作用型放大器很容易变换成反作用型放大器。
⑥耐压防爆型可在现场进行调整
由于信号(4~20mA.DC)输入端接头及线圈部位的封装呈耐压防爆结构,因此在进行检修及行程调整时,可以在现场防爆区域内拆除定位器外壳。
⑦本质**的构造有着广阔的适用范围
接线盒及线圈有着本质**型的构造,因此与专用的齐纳**栅组合使用能使力矩线圈适用于所有危险气体的场所(包括0区),使用环境温度范围为-40~+60℃。
3.FEATURES
①USABLE WITH SMALL AND LARGE CAPACITY ACTUATORS
By adjusting the built-in capacity control spring,the positioner can be made optimum to the given actuator.
②LOW AIR CONSUMPTION
The relay is low in air consumption and large in capacity.
③OUTPUT CHARACTERISTICS SELECTABLE
Having a cam within the feedback construction,choices other than the standard linear characteristic available.
④COMPATIBLE WITH VARIOUS FEEDBACK TYPES
Applicable to the following types by simply exchanging the cam block.
*For Linear type actuator:Feedback for Standard lever type∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙EP 6 1
*For Rotary type actuator:Feedback for Standard lever type∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙EP 6 2
⑤REVERSE ACTION RELAY EASILY AVAILABLE
The positive acting relay can be used as a reverse action relay when combined with a single acting actuator that requires a reverse action control.
⑥EXPLOSION PROOF STRUCTURE MARKING ON-SITE ADJUSTMENT POSSIBLE
Explosion proof construction,with the terminal and coil blocks enclosed together in one package,makes it possible to remove the positioner cover for inside inspection or span adjustment even in an explosive ambient.
⑦INTRINSICALLY SAFE CONSTRUCTION FOR A WIDE RANGE OF APPLICATIONS