MODEL
VAT-H200-5
OUTPUT
DC Output
5V
Rated Current
40A
Current Range Note 1
0~40A
Ripple and Noise
Note 2
0~65℃
200mV
Voltage ADJ. Range
±10% of rated output voltage
Voltage Accuracy
±2.0%
Line Regulation
±0.5%
Load Regulation
Set-up Time
<2.0S (220Vac input, Full load)
Hold up Time
>10mS(220Vac input, Full load)
Temperature Coefficient
±0.03%/℃
Overshoot and Undershoot
<5.0%
INPUT
Voltage Range
176Vac~264Vac
Frequency Range
47Hz~63Hz
Efficiency ( Typical)
81%(220Vac input)
AC Current (max.)
2.5A
Inrush Current (Typical)
45A@220Vac Cold start
Leakage Current
Input—output:<0.25mA Input—PG:<0.5mA
PROTECTION
Over Power
105%~150% of rated output power, auto recovery
Over Current
105%~150% of rated output current, auto recovery
Over Voltage
105%~150% of rated output voltage, auto recovery
Shorted Circuit
Long-term mode, auto recovery
ENVIRONMENT
Operating amb. Temp. & Hum.
-40℃~65℃; 20%~90%RH No condensing
Storage Temp. & Hum.
-40℃~85℃; 10%~95%RH No condensing
SAFETY &EMC
Note 3
Safety Standards
GB4943-2001; EN60950-1:2006
Withstand Voltage
Primary-Secondary:3.0KVac; ≤10mA .Primary-PG:1.5KVac; ≤10mA. Secondary-PG:0.5KVDC;≤10mA.
Isolation Resistance
≥100M ohms
EMI Conduction&Radiation
/
Harmonic Current
EMS Immunity
Compliance to EN61000-4-2,3,4,5,6,8,11;ENV50204,light industry level,criteriaA
OTHERS
MTBF (MIL-HDBK-217F)
More than 100,000Hrs (25℃, Full load)
Dimension (L*W*H)
199×99×50mm
Packing
Cooling method
Cooling by free air convection
NOTE
1. All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature.
2. Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor.
3. The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives.