SPECIFICATIONS | MODEL | 7110 | 7112 | 7120 | 7122 | AC WITHSTAND VOLTAGE | Output Rating | 5KVAC/12mA | | Range | Resolution | Accuracy | Output Voltage, KVAC | 0-5.00 | 0.01 | ±(2% of setting + 5V) | Output Frequency | 50Hz/60Hz ±100ppm, User Selection | Output Waveform | Sine Wave ,THD.<2% (Resistive Load), Crest Factor = 1.3 - 1.5 | Output Regulation | ± (1% of output + 5V), From no load to full load | SETTINGS | Hi-Limit AC Current, mA | 0.10 - 12.00 | 0.01 | ±(2% of setting + 2counts) | Lo-Limit AC Current, mA | 0.00 - 12.00 | 0.01 | ±(2% of setting + 2counts) | Ramp Time, second | 0.1 - 999.9 | 0.1 | ±(0.1% + 0.05sec) | Dwell Time, second | 0, 0.2 - 999.9 (0=continuous) | 0.1 | Arc Detection | 0, 1 - 9 ranges (0=OFF, 9 is the most sensitivity) | DC WITHSTAND VOLTAGE (7120,7122 ONLY) | Output Rating | 6KVDC/5mA | Output Voltage, KVDC | 0 - 6.00 | 0.01 | ±(2% of setting + 5V) | Output Ripple | <5%(6KV/5mA at Resistive Load) | SETTINGS | Hi-Limit DC Current, mA | 0.02 - 5.00 | 0.01 | ±(2% of setting + 2counts) | Lo-Limit DC Current, mA | 0.00 - 5.00 | 0.01 | ±(2% of setting + 2counts) | Ramp Time, second | 0.1 - 999.9 | 0.1 | ±(0.1% + 0.05sec) | Dwell Time, second | 0, 0.2 - 999.9 (0=continuous) | 0.1 | Arc Detection | 0, 1 - 9 ranges (0=OFF, 9 is the most sensitivity) | Discharge Time | ≦ 200 msec | INSULATION RESISTANCE (7112,7122 ONLY) | Output Rating | 1KVDC/1000MΩ | Output Voltage, KVDC | 0.10 - 1.00 | 0.01 | ±(2% of setting + 3V) | SETTINGS | Hi-Limit Resistance, MΩ | 0, 1 - 1000 (0=OFF) | 1 | ±(3% of setting+2counts)at > 500VDC | Lo-Limit Resistance, MΩ | 1 - 1000 | 1 | ±(7% of setting +2counts)at <500VDC | Delay Time, second | 0, 0.5 - 999.9 (0=continuous) | 0.1 | ±(0.1% + 0.05sec) | MEASUREMENT | AC/DC Voltage, KV | 0 - 6.00 | 0.01 | ±(1.5% of reading + 1count) | DC Voltage, KV (IR only) | 0.10 - 1.00 | 0.01 | ±(1.5% of reading + 3V) | AC Current, mA | 0.10 - 12.00 | 0.01 | ±(2% of reading + 2counts) | DC Current, mA | 0.02 - 5.00 | 0.01 | ±(2% of reading + 2counts) | Resistance, MΩ | 1 - 1000 (Auto Range) | 0.001 0.01 0.1 | ±(3% of reading+2counts)at > 500VDC ±(7% of reading +2counts)at <500VDC | GENERAL | Input Voltage AC | 115/230Vac±15%, 50/60Hz ± 5%, Fuse 3.15A Fast | PLC Remote Control | Input : Test , Reset | Output : Pass , Fail , Processing | Memory | 5 Sets Store/Recall of each Memory, 4 Test Mode Selectable (W, I, W~I, I~W Only 7112, 7122) | Display | 16×2 LCD with back light | Key Lock | To prevent unauthorized alteration of the test Parameters | Calibration | Build-in software and external calibrated meters | Environment | 0-40℃, 20-80%RH | Dimension/Net Weight | 280mm(W)×89mm(H)×370mm(D)/ 9Kg | STANDARD ACCESSORIES | Power Cord(10A) | ×1 | Fuses | ×3 (Including a spare contained in the fuse holder) | Hipot Test Lead ,1.5m(1101) | ×1 | Hipot Return Lead ,1.8m(1102) | ×1 | *product specifications are subject to change without notice. |
|