General Purpose Industrial Pressure Transducer - Vacuum to 6000 psi (400 bar)
Quick Specs...
Overview / Design Principle:
The 2200 series pressure transducer features stability and accuracy in a variety of enclosure options. The 2200 series pressure transducer feature proven CVD sensing technology, an ASIC (amplified units), and modular packaging to provide a sensor line that can easily accommodate specials while not sacrificing high performance.
Typical Applications:
Input
Pressure Range
Vacuum to 400 bar (6000 psi)
Proof Pressure
2 x Full Scale (FS) (1.5 x Fs for 400 bar, >= 5000)
Burst Pressure
>35 x FS <= 6 bar (100 psi); >20 x FS >=60 bar
Fatigue Life
Designed for more than 100 million FS cycles
Performance
Long Term Drift
0.2% FS/year (non-cumulative)
Accuracy
0.25 % FS typical (optional 0.15% FS)
Thermal Error
1.5% FS typical (optional 1% FS)
Compensated Temperatures
-20° C to 80° C (-5° F to 180° F)
Operating Temperatures
-40° C to 125° C (-22° F to 260° F) for elec. codes A, B -20° C to 80° C (-5° F to 180° F) for elec. codes 2, D -20° C to 50° C (-5° F to 125° F) for elec. codes F
Zero Tolerance
1% of span
Span Tolerance
Response Time
0.5 ms
Mechanical Configuration
Pressure Port
See ordering chart
Wetted Parts
17-4 PH Stainless Steel
Electrical Connection
Enclosure
316 SS, 17-4 PH ss IP65 for elec. codes A, B, D, 2 IP67 for elec. codes F IP30 for elec. code "3" with flying leads
Vibration
70g, peak to peak sinusoidal, 5 to 2000 Hz (Random Vibration: 20 to 2000 Hz @ approx. 20g Peak per MIL-STD.-810E Method 514.4)
Acceleration
100g steady acceleration in any direction 0.032% FS/g for 1 bar (15 psi) range decreasing logarithmically to 0.0007% FS/g for 400 bar (6000 psi) range
Shock
20g, 11 ms, per MIL-STD.-810E Method 516.4 Procedure l
Approvals
CE, UR (22ET, 26ET Intrinsically safe)
Weight
Approx. 100 grams (additional; cable 75 g/m)
Millivolt Output Units
Output
100 mV +/- mV
Supply Voltage (Vs)
10 Vdc (15 Vdc max.) Regulated
Bridge Resistance
2600-6000 ohms
Voltage Output Units
1.5 Vdc above span to 35 Vdc @ 6 mA
Supply Voltage Sensitivity
0.01% FS/Volt
Min. Load Resistance Current Consumption
(FS output / 2) K ohms approx. 6 mA at 7.5V output
Current Output Units
4-20 mA (2 wire)
24 Vdc, (7-35 Vdc) Above 100°C supply limited
Max. Loop Resistance
(Vs-7) x 50 ohms
沪公网安备 31011202007392号