HI2300型微电脑多功能台式电导率仪产品介绍: HI2300是微电脑控制,电导/总固体溶解度/氯化钠台式测量仪。其独特的自动选择量程功能可根据测量样品自动识别和选择量程,无需更换探头。仪器采用手动或自动方式进行温度补偿,用户可自主选择温度系数值。也可关闭此功能进行实际的电导测量。仪器还设有稳定指示器,用以提醒用户何时记录测量结果。HI2300还含有GLP性能,存储的数据可通过RS232接口输入计算机。另外,用户需输入的ID号码以鉴别仪器。标准配置:★HI2300型测量仪主机 HI76310具有ATC四环电导电极 相关附件。★HI2300P型测量仪主机 HI76310具有ATC四环电导电极 携带箱 相关附件。技术规格: 测量指标电导率(EC)总固体溶解度(TDS)测量范围(20℃或25℃温度补偿)0.00 to 29.99μS/cm(30.0 to 299.9μS/cm) 300 to 2999μS/cm (3.00 to 29.99mS/cm)30.0 to 200.0mS/cmUp to 500.0mS/cm(不进行温度补偿时测量电导值)0.00 to 14.99ppm(15.0 to 149.9ppm)150 to 1499ppm (1.50 to 14.99g/l)15.0 to 100.0g/lUp to 400.0g/l(不进行温度补偿时测量TDS值)解 析 度0.01μS/cm(0.00 to 29.99μS/cm)0.1μS/cm(30.0 to 299.9μS/cm)1μS/cm(300 to 2999μS/cm)0.01ms /cm(3.00 to 29.99ms/cm)0.1mS/cm(30.0mS/cm以上)0.01ppm(0.00 to 14.99ppm)0.1ppm(15.0 to 149.9ppm)1ppm(150 to 1499ppm)0.01g/l(1.50 to 14.99g/l)0.1g/l(15.0g/l以上)精 确 度±1%读数±(0.05μS/cm测量值)±1%读数±(0.03ppm测量值)校 正 点内设六个校正点自动识别电导校正同时TDS自动识别校正转换因子__0.40 to 0.80(出厂默认值0.50)温度补偿自动或手动补偿0 to 60℃自动或手动补偿0 to 60℃温度补偿常数0.00 to 6.00%/℃(出厂默认值1.90%/℃)测量指标盐度(NaCl)温度(℃)测量范围0.0 to 400.0%0.0 to 60℃解 析 度0.10%0.1℃精 度±1%读数±0.4℃校 正 点单点自动识别校正(推荐校正液HI7037)2个温度校正点0℃和50℃(调整间隔±1℃)配套电极HI76310具有ATC功能四环高性能电导电极(电导常数K=1)数据接口RS232配套电源HI710006专用220V/12VDC电源适用环境0.0 to 50.0℃ 95%RH尺寸/重量240×182×74mm/1200g