美国UVP公司CL-1000L实验室紫外交联仪95-0228-02 Ultraviolet Crosslinkers 德国耶拿分析仪器 Analytik Jena AG 2013年收购了美国UVP 利用长波紫外线提供均匀强度的UV照射。内部尺寸305X254x127mm,外部尺寸349x400x222mm 主要特点 占地面积小,台式使用 紫外强度和曝光时间可预设或手动调节 预曝光提供120,000微焦耳或五分钟的曝光 微处理器测量和控制紫外输出,可设置达999.9mj/cm的UV能量 5个365nm的长波紫外灯管提供均匀的紫外线 紫外**门锁设计 大型LED显示屏和触摸屏,显示时间或能量设置 门上的窗口允许观察过程,同时阻挡紫外线辐射 短波UV型可选择门(CL-1000)或抽屉(CX-2000)样式 内置UV传感器在UVP工厂进行校准,以确保准确性和可靠性 与烘烤相比,将核酸连接到膜上的交联需要几秒钟 规格 显示:LED 控制:触摸板 波长:365nm 紫外线曝光输出:120,000微焦耳或5分钟(可调);紫外能量设置为999,900微焦/平方厘米 瓦特:8瓦 应用 核酸的膜固定 EB染色的DNA缺刻 检测recA 功能 利用胸腺嘧啶二聚体抑制切割进行基因作图 紫外** PCR污染消减等 型号
型号
115V
230V
紫外光谱波长
可替换灯管
CL-1000
95-0174-01
95-0174-02
254nm
34-0007-01
CL-1000L
95-0228-01
95-0228-02
365nm
34-0006-01
CL-1000M
95-0230-01
95-0230-02
302nm
34-0042-01
CX-2000
95-0339-01
95-0339-02
美国UVP公司CL-1000L实验室紫外交联仪95-0228-02 的英文介绍: Ultraviolet Crosslinkers Chamber supplies uniform intensity overhead UV exposure of materials. The CL-1000 model is an exposure instrument, which utilizes shortwave ultraviolet energy to bond the DNA to a medium. Applications Shortwave 254nm UV: UV crosslinking membranes Longwave 365nm UV: UV curing, non-destructive testing Midrange 302nm UV: Photochemical reactions, UV crosslinking Main Features Small footprint for benchtop use Preset and manual controls for ultraviolet or time exposures Preset exposure delivers 120,000 microjoules or five minutes of exposure Microprocessor measures and control UV output, ensuring maximum energy efficiency Large LED display and touch panel which displays time or energy settings Window on the door allows viewing of the process yet blocks out the UV radiation Select from models with 302nm midrange UV, 365nm longwave UV or 254nm shortwave UV Overhead UV supplies uniform UV Shortwave UV model is available with choice of door (CL-1000) or drawer (CX-2000) styles Built-in UV sensor is calibrated at the UVP factory to ensure accuracy and reliability Crosslinking for attaching nucleic acids to a membrane takes seconds as compared to oven baking Specifications Display: LED Controls: Touch pad UV exposure output: 120,000 microjoules or 5 minutes (adjustable); maximum UV energy setting of 999,900 microjoules per cm2 Watts: 8 watt UV Source: CL-1000 254nm CL-1000M 302nm CL-1000L 365nm CX-2000 254nm Dimensions: CL-1000 models Exterior: 13.75D x 15.75W x 8.75H in. (349 x 400 x 222mm) Interior: 12D x 10W x 5H in. (305 x 254 x 127mm) Dimensions: CX-2000 models Exterior: 15D x 17.5W x 9.75H in. (381 x 445 x 248mm) Interior: 11.4W x 11.3D x 3.6H in. (290 x 287 x 91mm) Options UV meters UV blocking eyewear Applications "The DNA Damage Project: The Socrates Fellows program, funded by the National Science Foundation, is a UCSD project run by BioBridge which partners graduate students with local high school teachers to bring current science into the high school classroom. The use of a UV crosslinker, provided by UVP, allowed one Socrates fellow to develop and implement a meaningful biotechnology experience with high school students exploring the concept of DNA damage."
Ordering Information
Part Numbers
Model
Wavelength
Replacement Tubes