首页 >>> 成功案例 >

成功案例

Datanet无线系统用于污水排放行业的监控

客户感言:有了Datanet系统,我们得以将流程简化,并节约化工原料和能源。

作为欧盟的一员,西班牙已颁布国家法律,以实现符合市政及工业废水的处理欧盟的要求。污水处理厂也面临着很大的压力,为有效地开展工作,可靠高效地对水资源的越来越大的压力作出反应。

Application: Waste Water Treatment 污水处理

Organization: INSPRISA, Spain

Background:As an EU member state, Spain has enacted national legislation to achieve compliance with EU requirements for the treatment of municipal and industrial waste waters. Treatment plants also face great pressure to work as effectively, reliably and efficiently as possible to respond to the increasing pressure on water resources.
项目背景:作为欧盟的一员,西班牙已颁布国家法律,以实现符合市政及工业废水的处理欧盟的要求。污水处理厂也面临着很大的压力,为有效地开展工作,可靠高效地对水资源的越来越大的压力作出反应。

About the Customer:Founded in 1992, INPRISA is a Spanish company that specializes in wastewater treatment. 
关于客户:INPRISA成立于1992年,是一家西班牙公司,专门从事污水处理。
INPRISA uses a series of waste water treatment processes including ion exchange, ultra-filtration, reverse osmosis, physio-chemical purification, filter presses, chrome recovery, evaporators and acid reclamation.
INPRISA使用一系列的废水处理工艺,包括离子交换,超滤,反渗透,物理化学净化,压滤机,铬回收,蒸发器和酸回收利用。

Key Customer Challenges:

· Precipitating out toxic materials from water requires treatment with a number of chemicals and constant pH, flow-rate, conductivity and temperature data to be recorded in a single module, determining the relationships between them.
沉淀出来的水中有毒物质,需要与一些化学物质和恒定的pH值,流量,电导率,温度数据仪器记录在一个模块中,以确定它们之间的关系。

· National and international guidelines for waste water directives demand full reports of treatment processes that satisfy administrative and also legal requirements. Data history must be detailed enough to establish how much wastewater received primary and secondary treatments, or nutrient reductions.
国家和国际关于废水处理的国际准则要求提供满足行政和法律规定的处理工艺的完整报告。历史数据必须足够详细,以确定有多少污受到**和二级处理,或营养物消解。

· In every treatment plant, the company needs to know where chemicals and energy are most used throughout the process, in the hope of pinpointing areas for savings. 
在每一个污水处理厂,客户需要知道整个处理过程中,什么地方化学原料和能源消耗多,终节约能源和成本。


DataNet Implementation:The installation comprises three DataNet DNL910 loggers, one repeater and one receiver monitor, as well as pH, conductivity and flow probes. The DataNet logger units are placed with pH and conductivity sensors in large waste-water basins, as well as in a pipe where flow is measured. The logger and sensor installation is located 200 meters from the receiver, which is located in the control room with a repeater for optimal transmission. The readings required range from pH 6-8 values, up to conductivity 800 uS/cm and flow 2.000 m3 /h and data is transmitted to the central computer every 15 minutes. Alarms when data crosses the pre-defined parameters are sent to the control room, and SMS alerts can also be applied, allowing technicians to immediately address issues that arise. Regularly the data is exported to Excel and spreadsheet reports produced for the Council of Water Control and Administration, to demonstrate adherence to water policy standards. INPRISA now offer the system as standard in all water processing installations
Datanet系统布置:
系统包括三个Datanet DNL910记录仪,一个中继器和一个接收器,以及pH,电导率和流量传感器。Datanet记录仪携带pH和电导率传感器被放置在大型污水池,以及需要监测流量的管道中。该记录仪和传感器安装距离接收器200m左右,接收器位于中控室,布置一个中继器来优化传输信号。读数范围在pH值6-8 ,电导率800 uS/cm,流量2.000立方米/小时,数据每15分钟被发送到中央计算机。当数据越过限值,Datanet系统会报警发送到控制室,并提供短信提醒,使技术人员可以立即解决出现的问题。数据定期导出到Excel表,并发送报表到水控制管理委员会,以表明符合水资源政策的标准。 INPRISA现在提供的系统作为所有水处理现场的标配。

Measurable Results:监测结论

· Unified data values presentation – for easily managed data from multiple channels, indicating the different treatment elements that occur simultaneously and allowing the entire water treatment system process to be evaluated for inefficiencies. 
统一的数据展现 - 多渠道很方便地管理数据,表明同时发生的不同处理元素,并实现对整个水处理系统工艺的效率进行评估。

· Effective trouble shooting  – protected data and reliable alerts. In the event of transmission loss, data is recorded and stored in the logger memory, as well as the network finding an alternative data transfer route. In the case of any malfunction during part of treatment system, the SMS alerts alarm system is applied.
有效的故障排除 - 受保护的数据和可靠的报警系统。传输信号微弱的情况下,数据被记录并存储在记录仪内存里,同时Datanet系统会自动寻找一个替代的数据传送路径。一旦系统局部发生故障,都会发送SMS报警。

· Generating Detailed Reports– customized to meet governmental waste water guidelines, the reports provide INPRISA clients with clear and comprehensive documents for regular submission to the local and EU authorities.
可生成详细的报表-定制报表可满足政府的废水指导规范,报告提供给INPRISA客户提供清晰**的文件,用于定期向当地和欧盟提交。

· Chemical and energy conservation – create a clear picture of the dynamics of the waste water treatment procedure, and spot inefficiencies in the system
节约化工原料和能源 - 清晰建立废水处理过程的动态画面,并且在系统中发现低效率

· Flexibility in a single system – not only  performing well as a temperature control monitoring tool, but also for process measurements, a single inexpensive transmitter with 4/20 mA, can obtain data and display in table or graph form, as well as indicate minimum and maximum values. 
系统灵活性 - 不仅表现为一个良好的温度控制的监控工具,同时也实现过程测量,一个价格低廉的4~20mA变送器可以获取数据,并以表格或图形的形式显示小和大值。

2 580,00 CNY 单价Datanet无线温湿度系统

本案例中文版权归上海醇安电子所有,严禁复制,违反必究!