上海乐丁电子科技有限公司
主营产品:手动气体采样器气体检测管气流发生器发烟管日本GASTEC气体采集器室内甲醛气体检测管远距离气体采样聚偏氟乙烯气体采集袋日本光明理化检测管GASTEC气体快速检知管便携式快速气体检测箱自动气体采样器GSP-300FT恶臭气体快速检测箱快速水质检测管北川式气体检测管日本进口气体采样袋

甲醛检测管NO. 91P

如果您对该产品感兴趣的话,可以
产品名称: 甲醛检测管NO. 91P
产品型号: NO. 91P
产品展商: 其它品牌
产品价格: 0.00 元

简单介绍
甲醛检测管NO. 91P,GASTEC甲醛检测管NO. 91P气体检测管,甲醛HCHO检测管NO. 91P,GASTEC甲醛检测管NO. 91P电泵用气体检测管检测范围0.02-1.44ppm。

甲醛检测管NO. 91P的详细介绍

甲醛检测管NO. 91P
甲醛检测管
NO. 91PGASTEC甲醛检测管NO. 91P气体检测管,甲醛HCHO检测管NO. 91P,GASTEC甲醛检测管NO. 91P电泵用气体检测管检测范围0.02-1.44ppm。
GASTEC为了满足用户在气体检测方面的需要,而开发出了电子自动采气泵。用传统的电子吸气泵几乎不能进行有效的采气,因为检测管里的填充试剂密度很高。而GASTEC开发的GSP电泵系列能提供强劲吸力,能满足特定的检测管的取样要求。电泵和检测管组成的新的检测系统能适用于作业环境的检测。

Formaldehyde

NO.91P
HCHO 
甲醛检测管NO. 91P
Specifications
Calibration Range0.02-0.4 ppm
Measuring range0.02-1.44 ppm
Sampling (flow) Rate200mL/min
Sampling Volume6000mL, 2000mL
Sampling Time30min, 10min.
Detecting Limit0.01 ppm
Colour ChangeYellow → pink
Corrections for temperature/humidityTemperature
Shelf life1 year (in the refrigerator)
AccuracyCV=5-10%
(CV: Coefficient of variation = σ: standard deviation / mean value x 100)
Possibly coexisting substances and their interferences
Substance(s)InterferenceColour change by itself
Ammonia2 ppm (or less)NoNo
Nitrogen dioxide1 ppm (or less)NoNo
Acetaldehyde "+" error
(higher reading)
produces pinkish discolouration
Acetone0.3 ppm (or less)NoProduces pinkish stain around tube opening (inlet)
Ethanol NoNo
Ethyl acetate NoNo
p-dichlorobenzene NoNo
Toluene NoNo

Scrubber 1 (black): removes acetone

Scrubber 2 (purple):
Ammonia and nitrogen dioxide are removed. The presence of ammonia causes the purple scrubber 2 to turn yellow.

The presence of nitrogen dioxide causes scrubber 2 to turn a darker shade of purple
Calibration gas generationDiffusion tube method (analysis: by absorptiometry, acetylacetone method)
Miscellaneous
Electric sampling pump
This detector tube is suited for measuring formaldehyde in indoor environments. The GSP-200 / GSP-300FT series automatic gas samplers (or comparable sampling devices/pumps) should always be used for optimal performance.
A deviation of +/-10% in the sampling flowrate (i.e. amount of air flowing through the tube at a given moment) or the sampling amount (total sampled amount of target substance) causes an average margin of error of approx. +/-10% (maximum +/-20%) in the indicated value.
Formaldehyde indoor concentration threshold: 0.08 ppm (mean value during 30 minutes)
TLV-TWATLV-STELExplosive range
-- -- C0.3ppm7.0×73%
产品留言
标题
联系人
联系电话
内容
验证码
点击换一张
注:1.可以使用快捷键Alt+S或Ctrl+Enter发送信息!
2.如有必要,请您留下您的详细联系方式!
  • 温馨提示:为规避购买风险,建议您在购买前务必确认供应商资质与产品质量。
  • 免责申明:以上内容为注册会员自行发布,若信息的真实性、合法性存在争议,平台将会监督协助处理,欢迎举报

甲醛检测管NO. 91P相关产品

产品搜索
联系方式
产品目录
Copyright@ 2003-2024  上海乐丁电子科技有限公司版权所有