首页 >>> 产品目录 >>> Controller & Indicator
仪表展览网 >>> 展馆展区 >>> 其他工控设备 >>> DCS系统 >>> Yokogawa TC/mV Input Module NFAT141-S50
> Yokogawa TC/mV Input Module NFAT141-S50

产品资料

Yokogawa TC/mV Input Module NFAT141-S50[产品打印页面]

Yokogawa TC/mV Input Module NFAT141-S50
  • 如果您对该产品感兴趣的话,可以
  • 产品名称:Yokogawa TC/mV Input Module NFAT141-S50
  • 产品型号:NFAT141-S50
  • 产品展商:Yokogawa
  • 产品文档:无相关文档
简单介绍
Yokogawa TC/mV Input Module NFAT141-S50, Yokogawa TC/mV Input Module NFAT141-S50, receive mV, thermocouple (TC) or RTD signals. 16-channel, Isolated.
产品描述

Manufacturer: Yokogawa Electric Corporation 

STARDOM

FCN, FCN-500, FCN-100, FCN-RTU, FCJ

Yokogawa TC/mV Input Module NFAT141-S50

Standard Specifications

TC Input/RTD Input Modules (Isolated)
These modules receive mV, thermocouple (TC) or RTD signals.

Yokogawa TC/mV Input Module NFAT141-S50

Items

Specifications

Model

NFAT141 (*6)

NFAR181

Number of input channels

16, isolated

12, isolated

 

 

 

Input signal

TC JIS C1602:1995, IEC60584:1989

Type J, K, E, B (*1), R, S, T, N

JIS C1602:1981, IEC60584:1977

Type J, K, E, B (*1), R, S, T, N

IEC60584:1977

Type N

mV -100 to 150 mv, -20 to 80 mv

RTD: JIS C 1604:1997, IEC 60751:1995

Pt100 (three-wire type)

JIS C 1604:1989, IEC 60751:1986

Pt100 (three-wire type) JIS C 1604:1989

JPt100 (three-wire type)

 

Switching input signals

TC/mV can be set individually for CH1 to

CH16.

 

Allowable input voltage

±5 V

±5 V

 

Withstanding voltage

Between input and system: 1500 V AC for 1

minute (*7)

Between input and system: 1500 V AC for 1 minute

 

Input resistance

Power ON

2 MΩ or more

Power OFF

2 MΩ or more

 

Accuracy

Thermocouple inputs:

±0.03% of full scale (for -20 to 80 mV)

mV inputs:

±0.032% of full scale (for -100 to 150 mV)

 

±0.03% of full scale (for 0 to 400 Ω)

Allowable total resistance of signal source plus wiring

 

1000 Ω or less

 

40 Ω or less (wiring resistance per wire)(*2)

Effect of allowable signal source resis-

tance (1000 Ω)

 

±20 μV

 

Reference junction compensation accuracy

 

Within ±1°C (*3, 4)

 

Measurement current

1 mA

 

Temperature drift

Thermocouple inputs: Max. ±30 ppm/°C

mV inputs: Max. ±32 ppm/°C

 

Max. ±30 ppm/°C

Data refresh cycle

1sec

 

Burn-out

All channels can be set together.

Setting: Not available/available (UP/DOWN)

detection time: 60 seconds

Maximum current consumption

450 mA(5 V DC)

450 mA (5 V DC)

Weight

0.2 kg

 

External connection

Pressure clamp terminal, MILconnector cable

(*5)(*7)

 

Pressure clamp terminal

*1: Type B does not carry out temperature compensation and can not measure under 44°C.
*2: Each wiring resistance should be equal. Yokogawa TC/mV Input Module NFAT141-S50
*5: Use a MIL connector cable for only mV input.
*6: The NFAT141 thermocouple input module imposes limitations in installation. See “Restrictions and Precautions on Installation”.
*7: The withstanding voltage for using MIL connector cable depends on the electrical specifications of its cable. If you are using KMS40 cable, withstanding voltage of between input and system is 500 V AC for 1 minute. 


Models and Suffix Codes 

Yokogawa TC/mV Input Module NFAT141-S50

 

 

Description

Model

NFAT141

TC/mV Input Module (16-channel, Isolated)

 

 

Suffix Codes

-S

Standard type

5

With no explosion protection

E

With explosion protection

0

Basic type

1

With ISA Standard G3 option

 

Option Codes

/T4S00

With Pressure Clamp Terminal Block for Thermocouple/mV [Model: NFTT4S-00]

/T4S10

With Pressure Clamp Terminal Block for Thermocouple/mV (surge absorber) [Model: NFTT4S-10]

/CCC01

With Connector Cover for MIL Cable [Model: NFCCC01]

产品留言
标题
内容
联系人
联系电话
电子邮件
公司名称
联系地址
验证码
点击换一张
注:1.可以使用快捷键Alt+S或Ctrl+Enter发送信息!
2.如有必要,请您留下您的详细联系方式!