Yokogawa Zirconia Oxygen Analyzer ZR22G-100-S-E-C-T-T-C-A Yokogawa Zirconia Oxygen Analyzer ZR22G-100-S-E-C-T-T-C-A used as both a Zirconia Oxygen Analyzer and High Temperature Humidity Anal
产品描述

Manufacturer: Yokogawa Electric Corporation

Yokogawa Zirconia Oxygen Analyzer ZR22G-100-S-E-C-T-T-C-A

This analyzer consists basically of a probe and a converter that are used as both a Zirconia Oxygen Analyzer and High Temperature Humidity Analyzer. The probe is of direct insertion type, and the converter uses a digital display.

 

Two types of analyzers are available: separate type and integrated type. As its name implies, the integrated type combines probe and converter.

 

Separate and integrated type Zirconia oxygen analyzers need not use a sampling device, and allow direct installation of the probe in the wall of a flue or furnace to measure the concentration of oxygen in the stack gas. The converter displays the cell temperature and cell emf in addition to the oxygen concentration.

 

This analyzer is most suitable for monitoring the oxygen concentration of combustion gases in large or small boilers, various industrial furnace and combustion devices, or for the control of low-oxygen combustion.

 

Separate type and integrated type Zirconia High Temperature Humidity Analyzers are used to measure the humidity of hot gases continuously in driers which use an electrical heater or hot gas as the heat source.

They can also be used in a variety of manufacturing applications in humidifiers, as well as in driers, for humidity measurement and control. They can help improve productivity in these application fields.


Features

  Yokogawa Zirconia Oxygen Analyzer ZR22G-100-S-E-C-T-T-C-A              

 The built-in heater assembly of the probe can be replaced on site, reducing maintenance costs.

 The probe uses a long-life, high-reliability Zirconia sensor.

 The probe uses three-reference gas supply methods (natural air convection, instrument air, and pressure compensated) in its applications.

 The separate type converter incorporates a LCD touch screen for ease of operation.

 This converter can be used as an oxygen analyzer as well as a high temperature humidity analyzer.

 The integrated type integrates both probe and converter, to reduce wiring, piping, and installation costs. This type of unit uses an optical switch for ease of operation at the site.

Remote maintenance using digital communications (HART) reduces maintenance costs.

 

General Specifications       

Yokogawa Zirconia Oxygen Analyzer ZR22G-100-S-E-C-T-T-C-A   

Measurement object Oxygen concentration in combustion exhaust gas and mixed gas.
Measurement system Zirconia system
Measurement range 0.01 to 100 vol%O2
Output signal 4 to 20 mA DC, two points (maximum load resistance 550 Ω)
Setting range Any setting in the range of 0 - 5 vol%O2 to 0 - 100 vol%O2 (in 1 vol%O2), or partial range
Digital communication (HART) 250 to 550 Ω, depending on number of field devices connected to the loop (multi-drop mode)
Sample gas pressure -5 to +250 kPa
Sample gas temperature 0 to 700°C (Probe only)
700 to 1400°C (with 0.15m probe and High Temperature Probe Adapter)
Probe length 0.15, 0.4, 0.7, 1.0, 1.5, 2.0, 2.5, 3.0, 3.6,4.2, 4.8, 5.4 m
Contact output Four points (one is fail-safe, normally open)
Contact input Two points
Calibration Method ; zero/span calibration
Calibration mode ;
automatic, semi-automatic and manual (All are operated interactively with an LCD touchscreen)
Construction of detector Heater and thermocouple replaceable construction. 
Non-explosion-proof. Equivalent to NEMA4X/IP66
Construction of converter Outdoor installation. Equivalent to NEMA4X/IP66
Ambient temperature Probe: -20 to 150°C
Converter: -20 to 55°C
Power supply 85 to 264 V AC; 45 to 66 Hz

 

Performance

 Yokogawa Zirconia Oxygen Analyzer ZR22G-100-S-E-C-T-T-C-A

Repeatability
±0.5% Maximum value of set range
Linearity ±1% Maximum value of set range
Drift ±2% Maximum value of set range/month
Response time 90% response within 5 sec
 

 

Model and Suffix Codes

Yokogawa Zirconia Oxygen Analyzer ZR22G-100-S-E-C-T-T-C-A   

Model - - - - - - - - ZR22G,  Separate type Zirconia Oxygen/ High Temperature Humidity Analyzer, Detector

 

Length

-015 - - - - - - - - - - 0.15 m (for high temperature use)         (*1)

-040 - - - - - - - - - - 0.4 m

-070 - - - - - - - - - - 0.7 m

-100 - - - - - - - - - - 1.0 m

-150 - - - - - - - - - - 1.5 m

-200 - - - - - - - - - - 2.0 m

-250 - - - - - - - - - - 2.5 m         (*2)

-300 - - - - - - - - - - 3.0 m         (*2)

-360 - - - - - - - - - - 3.6 m         (*2)

-420 - - - - - - - - - - 4.2 m         (*2)

-480 - - - - - - - - - - 4.8 m         (*2)

-540 - - - - - - - - - - 5.4 m         (*2)

 

Wetted material

-S - - - - - - - - - - - Stainless steel

-C - - - - - - - - - - - Stainless steel with Inconel calibration gas tube     (*10)

 

Flange  (*3)

-A - - - - - - - - - - ANSI Class 150 2 RF SUS304 (JIS)

-B - - - - - - - - - - ANSI Class 150 3 RF SUS304 (JIS)

-C - - - - - - - - - - ANSI Class 150 4 RF SUS304 (JIS)

-E - - - - - - - - - - DIN PN10 DN50 A SUS304 (JIS)

-F - - - - - - - - - - DIN PN10 DN80 A SUS304 (JIS)

-G - - - - - - - - - - DIN PN10 DN100 A SUS304 (JIS)

-K - - - - - - - - - - JIS 5K 65 FF SUS304 (JIS)

-L - - - - - - - - - - JIS 10K 65 FF SUS304 (JIS)

-M - - - - - - - - - - JIS 10K 80 FF SUS304 (JIS)

-P - - - - - - - - - - JIS 10K 100 FF SUS304 (JIS)

-Q - - - - - - - - - - JIS 5K 32 FF SUS304 (JIS) (for high temperature use)   (*4)

-R - - - - - - - - - - JPI Class 150 4 RF SUS304 (JIS)

-S - - - - - - - - - - JPI Class 150 3 RF SUS304 (JIS)

-W - - - - - - - - - - Westinghouse

 

Reference gas

-C - - - - - - - - - - Natural convection  

-E - - - - - - - - - - External connection (Instrument air)     (*11)  

-P - - - - - - - - - - Pressure compensated       (*11)

 

Gas Thread

-R - - - - - - - - - - Rc1/4  

-T - - - - - - - - - - 1/4NPT(Female)

 

Connection box thread

-P - - - - - - - - - - G1/2

-G - - - - - - - - - - Pg13.5

-M - - - - - - - - - - M20 x1.5

-T - - - - - - - - - - 1/2 NPT

-Q - - - - - - - - - -  Quick connect          (*9)

 

Instruction manual

-J - - - - - - - - - - Japanese

-E - - - - - - - - - - English

-C - - - - - - - - - - Chinese

 

-A - - - - - - - - - -  Always -A  

 

Options

Valves

/C,  Inconel bolt              (*5)

/CV, Check valve             (*6)

/SV, Stop valve                (*6)

Filter

/F1, Dust Filter                 (*7)  

/F2, Dust Guard Protector     (*7)

Tag plates

/SCT, Stainless steel tag plate         (*8)

/PT,   Printed tag plate                      (*8)