Setra Model286/256 Pressure Transducer
Applications
Process Control
Chemical Processing
Agricultural Irrigation Systems
Natural Gas Pipeline Monitoring
Grain Processing
Industrial Pressure Monitoring
Model 256 Specifications
Electrical Output (Voltage)
0.1 to 5.1 VDC
Electrical Output (Current) 4 to 20 mA
Accuracy
(RSS Method) ±0.13% Full Scale for ranges 25 psi and higher
±0.25% Full Scale for ranges less than 25 psi
Type of Pressure Gauge
Pressure Ranges 0 to 2, 5, 10, 25, 50, 100, 250, 500,
600, 1000, 3000, 5000, 10,000 psig
1.6, 4, 6, 10, 16, 25, 40, 60, 100, 160,
250, 400, 700 bar
Thermal Effects Compensated Range °F (°C):
-4 to +176 (-20 to +80)
Ranges 25 PSI and Higher:
Zero Shift %FS/100°F(50°C): 1.0 (0.9)
Span Shift %FS/100°F(50°C): 1.5 (1.4)
Ranges Less Than 25 PSI:
Zero Shift %FS/100°F(50°C): 2.0 (1.8)
Span Shift %FS/100°F(50°C): 1.5 (1.4)
Media Gases or liquids compatible with 17-4PH
stainless steel. (Hydrogen not recommended for use with 17-4PH stainless steel)