经济型粉末电阻率测试仪
型号及技术指标Models and technical indicators:
经济型粉末电阻率测试仪
规格型号 model |
FT-300I |
FT-300II |
FT-300III |
FT-300Ⅳ |
|||
1.电阻resistance |
10-7~2×107Ω |
10-6~2×106Ω |
10-5~2×106Ω |
10-4~1×105Ω |
|||
2.电阻率范围Resistivity |
10-7~2×107Ω-cm |
10-6~2×106Ω-cm |
10-5~2×106Ω-cm |
10-4~1×105Ω-cm |
|||
3.电导率Conductivity |
5×10-7~107s/cm |
5×10-6~106s/cm |
5×10-6~105s/cm |
5×10-5~104s/cm |
|||
4.测试电流范围 current |
1μA,10μA,100µA,1mA,10mA,1000mA |
1μA,10μA,100µA,1mA,10mA, |
|||||
5.测量电压量程Voltage |
测量电压量程 voltage:2mV 20mV 200mV 2V 测量精度Accuracy±(0.1%读数) 分辨率 Resolution: 0.1uV 1uV 10uV 100uV |
||||||
6.电流精度Current |
±0.1%Accuracy |
±0.2% Accuracy |
±0.2% Accuracy |
±0.3% Accuracy |
|||
7.电阻精度Resistance Accuracy |
≤0.3%标准电阻resistance |
≤0.3%标准电阻resistance |
≤0.3%标准电阻resistance |
≤0.5%标准电阻 standard resistance |
|||
8.显示读数display |
液晶显示:电阻值、电阻率、电导率值、温度、压强值、单位自动换算、横截面、高度,超上下限警报 LCD: resistance, resistivity, conductivity, temperature, pressure value, the unit automatically conversion, cross-section, height,Super and upper limit alarm |
||||||
9.测试方式Test mode |
四端测量法Four-terminal measurement method |
||||||
10.传感器压力Pressure Sensors |
200kg;(其他规格可以定制) (Other specifications can be customized) |
||||||
11.粉末测量装置 Powder measuring device |
模具Mold:内径inner diameter 10mm; 20mm(选购), height: 25mm, 加压方式:手动液压加压测量 pressure: manual hydraulic pressure / automatic compression mode (purchase). |
||||||
12.工作电源power supply |
输入: AC 220V±10% ,50Hz 功 耗Power consumption:<30W |
||||||
13.外形尺寸/dimensions |
主机Mainframe:约L330mm*D350mm*H120mm ;手动装置about:约H450mm*L200mm*D120mm |
||||||
14.净重量/Net Weight |
约35kg About 35kg |
||||||
15. 标配外选购Others buy |
a.标准校准电阻1-5个;b.PC软件一套;c.电脑和打印机依据客户要求配置;d.计量证书1份 ,e. 高度校准塞规1个 a. Standard calibration resistor 1-5. b.PC software 1 set c. computers and printers based on customer configuration requirements. d. Measurement certificate 1. e. Height calibrated plug gauge 1 pcs |
||||||
步骤及流程
1.运行高度清零.
2.将称重样品装入模腔.
3.固定上电极旋钮.
4.在显示器上设置好参数.
5.达到设定压力或压强值.
经济型粉末电阻率测试仪
6.读取样品压缩高度数据并输入.
7.获得电阻、电阻率、电导率数据.
8.记录数据.
9. 样品脱模
7. 测试结束.
经济型粉末电阻率测试仪