GLOW WIRE TEST APPARATUS
Technical parameters:
1, glow wire temperature: 500 ~ 1000℃± 2℃continuous adjustable
2, hot time: 0-999.9 s + /-0.1 s adjustable (generally choose for 30 s)
3 and light-off time: 0-999.9 s + /-0.1 s, automatic records, wire control pause
4, put out time: 0-999.9 s + /-0.1 s, automatic records, wire control pause
5, thermocouple: Φ 0.5 mm import armoured thermocouple (K) type
6, glow wire: Φ 4 mm PTCRS (Ni80 / Cr20)
7, iron into depth: 7 mm + /-0.5 mm
8, sample pressure: 1 N + /-0.2 N
9, test speed: 18 ± 3 mm/s.
10, U head standard: IEC60695-2-10.
11, test process: test program automatic control, independent convulsions
12, consult standard GB/T5169.10-2006, IEC60695-2-10:20 00, UL746A
13, studio: greater than 0.5 cubic volume, (but according to customers\' special requirements 0.75 cubic or 1 cubic)
14, the equipment size: 1100 mm wide x 700 mm deep x 1300 mm
15, control: USES the monolithic microcomputer + touch screen control, the high accuracy thermometer independent type electrical control system, anti-jamming can
16, operation efficiency: test control processes to achieve a key type operation, fast and efficient test,
17, test standards according to actual test process integration: write test procedures.