Manufacturer: Yokogawa Electric Corporation
Yokogawa Paperless Recorder FX1002-4-3-H/A1/USB1
Model and Suffix Code for Yokogawa Paperless Recorder FX1002-4-3-H/A1/USB1
Model code Suffix code Optional code Description FX1002 2ch, Shortest measurement interval: 125ms FX1004 4ch, Shortest measurement interval: 125ms FX1006 6ch, Shortest measurement interval: 1s FX1008 8ch, Shortest measurement interval: 1s FX1010 10ch, Shortest measurement interval: 1s FX1012 12ch, Shortest measurement interval: 1s External storage medium slot -0 Without CF card slot and medium (Note) -4 With CF card slot and medium Language -2 English/Japanese/German/French/Chinese/Italian/Spanish/Portuguese/ Russian/Korean, deg F and DST Withstanding voltage between measuring input terminals -H 1000 VAC(50/60 Hz), 1 min -L 400 VAC(50/60 Hz), 1 min Options /A1 Alarm output 2 points (C-contact)*1*10 /A2 Alarm output 4 points (C-contact)*1 /A3 Alarm output 6 points (C-contact)*1*3 /A4A Alarm output 12 points (A-contact)*1*3 /C2 RS-232 interface*2 /C3 RS-422A/485 interface*2 /C7 Ethernet interface /F1 FAIL/Status output*3 /M1 Mathematical functions (including Report functions) /N2 3 leg isolated RTD*4 /N3F Extended input type (without Pt1000) /P1 24 VDC/AC power supply /R1 Remote control 8 points*5 /TPS2 24VDC transmitter power supply (2 loops)*6*10 /TPS4 24VDC transmitter power suply (4 loops)*7 /USB1 USB interface (1 port) /PM1 Pulse input 3 points, Remote control 5 points (including Mathematical functions)*8 /CC1 Calibration correction function /LG1 Log scale /PWR1 Power monitor (including Mathmatical functions)*9*10
Model code
Suffix code
Optional code
Description
FX1002
2ch, Shortest measurement interval: 125ms
FX1004
4ch, Shortest measurement interval: 125ms
FX1006
6ch, Shortest measurement interval: 1s
FX1008
8ch, Shortest measurement interval: 1s
FX1010
10ch, Shortest measurement interval: 1s
FX1012
12ch, Shortest measurement interval: 1s
External storage medium slot
-0
Without CF card slot and medium (Note)
-4
With CF card slot and medium
Language
-2
English/Japanese/German/French/Chinese/Italian/Spanish/Portuguese/ Russian/Korean, deg F and DST
Withstanding voltage between measuring input terminals
-H
1000 VAC(50/60 Hz), 1 min
-L
400 VAC(50/60 Hz), 1 min
Options
/A1
Alarm output 2 points (C-contact)*1*10
/A2
Alarm output 4 points (C-contact)*1
/A3
Alarm output 6 points (C-contact)*1*3
/A4A
Alarm output 12 points (A-contact)*1*3
/C2
RS-232 interface*2
/C3
RS-422A/485 interface*2
/C7
Ethernet interface
/F1
FAIL/Status output*3
/M1
Mathematical functions (including Report functions)
/N2
3 leg isolated RTD*4
/N3F
Extended input type (without Pt1000)
/P1
24 VDC/AC power supply
/R1
Remote control 8 points*5
/TPS2
24VDC transmitter power supply (2 loops)*6*10
/TPS4
24VDC transmitter power suply (4 loops)*7
/USB1
USB interface (1 port)
/PM1
Pulse input 3 points, Remote control 5 points (including Mathematical functions)*8
/CC1
Calibration correction function
/LG1
Log scale
/PWR1