GENERAL SPECIFICATIONS

Yokogawa Paperless Recorder FX1002-4-2-H/A1/USB1

Construction

Mounting: Flush panel mounting (on a vertical plane) Mounting may be inclined downward up to 30 degrees from a horizontal plane.
Allowable panel thickness: 2 to 26 mm
Front panel: Water- and dustproof: Complies with IEC529-IP65 (excluding side-by-side mounting)

Input

Yokogawa Paperless Recorder FX1002-4-2-H/A1/USB1

Number of inputs: FX1002: 2 channels, FX1004: 4 channels, FX1006: 6 channels, FX1008: 8 channels, FX1010: 10 channels, FX1012: 12 channels
Measurement intervals: FX1002, DX1004: 125 ms, 250 ms FX1006, FX1008, FX1010, FX1012: 1 s, 2 s, 5 s
Inputs: DCV (20, 60, 200 mV, 1, 2, 6, 20, 50 V, 1-5 V) TC (R, S, B, K, E, J, T, N, W, L, U, WRe) RTD (Pt100, JPt100) DI (Contact input, TTL level) DCA (with external shunt resistor attached)
Measurement/display accuracy: Standard operating conditions: Temperature: 23 ± 2°C Humidity: 55% ± 10%RH Power supply voltage: 90 to 132 or 180 to 250 VAC Power supply frequency: 50/60 Hz ± 1% Warm-up time: At least 30 minutes. Other ambient conditions such as vibration should not adversely affect the operation.
Input Range Measurement Accuracy Digital Display Max. Resolution
DCV 1-5 V ±(0.05% of rdg+3 digits) 1 mV
Thermocouple* K ±(0.15% of rdg + 0.7°C) –200 to –100°C: ±(0.15% of rdg + 1°C) 0.1°C
RTD Pt100 ±(0.15% of rdg+0.3°C) 0.1°C 0.1°C

* Does not include the accuracy of reference junction compensation

Model and Suffix Code


Model code

Suffix code

Optional code

Description

FX1002

 

 

 

 

2ch, Shortest measurement interval: 125ms

FX1004

 

 

 

 

4ch, Shortest measurement interval: 125ms

FX1006

 

 

 

 

6ch, Shortest measurement interval: 1s

FX1008

 

 

 

 

8ch, Shortest measurement interval: 1s

FX1010

 

 

 

 

10ch, Shortest measurement interval: 1s

FX1012

 

 

 

 

12ch, Shortest measurement interval: 1s

External storage medium slot

-0

 

 

 

Without CF card slot and medium (Note)

-4

 

 

 

With CF card slot and medium

Language

-2

 

 

English/Japanese/German/French/Chinese/Italian/Spanish/Portuguese/ Russian/Korean, deg F and DST

Withstanding voltage between measuring input terminals

-H

 

1000 VAC(50/60 Hz), 1 min

-L

 

400 VAC(50/60 Hz), 1 min

Options

/A1

Alarm output 2 points (C-contact)*1*10

/A2

Alarm output 4 points (C-contact)*1

/A3

Alarm output 6 points (C-contact)*1*3

/A4A

Alarm output 12 points (A-contact)*1*3

/C2

RS-232 interface*2

/C3

RS-422A/485 interface*2

/C7

Ethernet interface

/F1

FAIL/Status output*3

/M1

Mathematical functions (including Report functions)

/N2

3 leg isolated RTD*4

/N3F

Extended input type (without Pt1000)

/P1

24 VDC/AC power supply

/R1

Remote control 8 points*5

/TPS2

24VDC transmitter power supply (2 loops)*6*10

/TPS4

24VDC transmitter power suply (4 loops)*7

/USB1

USB interface (1 port)

/PM1

Pulse input 3 points, Remote control 5 points (including Mathematical functions)*8

/CC1

Calibration correction function

/LG1

Log scale

/PWR1

Power monitor (including Mathmatical functions)*9*10

Note: To load data, the FX must be equipped with a communication interface (/C2, /C3, or /C7 option) or the USB interface (/USB1 option).

*1       Any combination of /A1, /A2, /A3, and /A4A cannot be specified together.

*2       /C2 and /C3 cannot be specified together.

*3       /A3 or /A4A cannot be specified together with /F1.

*4       /N2 cannot be specified for FX1002 or FX1004.

*5       If /R1 is specified, /A4A, /TPS2, /TPS4, /PM1, or /PWR1 cannot be specified.

*6       If /TPS2 is specified, /TPS4, /A2, /A3, /A4A, /F1, /R1, or /PM1 cannot be specified.

*7       If /TPS4 is specified, /TPS2, /A1, /A2, /A3, /A4A, /F1, /R1, or /PM1 cannot be specified.

*8       If /PM1 is specified, /A4A, /M1, /R1, /TPS2, /TPS4, or /PWR1 cannot be specified.

*9       If /PWR1 is specified, /A3, /A4A, /F1, /R1, /PM1, or /M1 cannot be specified.

     *10    /TPS2, /PWR1, and /A1 cannot be specified together.