Manufacturer: Yokogawa Electric Corporation
Yokogawa Paperless Recorder FX1002-7-2-L
GENERAL SPECIFICATIONS
Yokogawa Paperless Recorder FX1002-7-2-L
Construction
Mounting:
|
Flush panel mounting (on a vertical plane) Mounting may be inclined downward up to 30 degrees from a horizontal plane.
|
Allowable panel thickness:
|
2 to 26 mm
|
Front panel:
|
Water- and dustproof: Complies with IEC529-IP65 (excluding side-by-side mounting)
|
Input
Yokogawa Paperless Recorder FX1002-7-2-L
Number of inputs:
|
FX1002: 2 channels, FX1004: 4 channels, FX1006: 6 channels, FX1008: 8 channels, FX1010: 10 channels, FX1012: 12 channels
|
Measurement intervals:
|
FX1002, DX1004: 125 ms, 250 ms FX1006, FX1008, FX1010, FX1012: 1 s, 2 s, 5 s
|
Inputs:
|
DCV (20, 60, 200 mV, 1, 2, 6, 20, 50 V, 1-5 V) TC (R, S, B, K, E, J, T, N, W, L, U, WRe) RTD (Pt100, JPt100) DI (Contact input, TTL level) DCA (with external shunt resistor attached)
|
Measurement/display accuracy:
|
Standard operating conditions: Temperature: 23 ± 2°C Humidity: 55% ± 10%RH Power supply voltage: 90 to 132 or 180 to 250 VAC Power supply frequency: 50/60 Hz ± 1% Warm-up time: At least 30 minutes. Other ambient conditions such as vibration should not adversely affect the operation.
|
Input
|
Range
|
Measurement Accuracy
|
Digital Display Max. Resolution
|
DCV
|
1-5 V
|
±(0.05% of rdg+3 digits)
|
1 mV
|
Thermocouple*
|
K
|
±(0.15% of rdg + 0.7°C) –200 to –100°C: ±(0.15% of rdg + 1°C)
|
0.1°C
|
RTD
|
Pt100
|
±(0.15% of rdg+0.3°C) 0.1°C
|
0.1°C
|
* Does not include the accuracy of reference junction compensation
Model and Suffix Code
Model code
|
Suffix code
|
Optional code
|
Description
|
FX1002
|
|
|
|
|
2ch, Shortest measurement interval: 125ms
|
FX1004
|
|
|
|
|
4ch, Shortest measurement interval: 125ms
|
FX1006
|
|
|
|
|
6ch, Shortest measurement interval: 1s
|
FX1008
|
|
|
|
|
8ch, Shortest measurement interval: 1s
|
FX1010
|
|
|
|
|
10ch, Shortest measurement interval: 1s
|
FX1012
|
|
|
|
|
12ch, Shortest measurement interval: 1s
|
External storage medium slot
|
-0
|
|
|
|
Without CF card slot and medium (Note)
|
-4
|
|
|
|
With CF card slot and medium
|
Language
|
-2
|
|
|
English/Japanese/German/French/Chinese/Italian/Spanish/Portuguese/ Russian/Korean, deg F and DST
|
Withstanding voltage between measuring input terminals
|
-H
|
|
1000 VAC(50/60 Hz), 1 min
|
-L
|
|
400 VAC(50/60 Hz), 1 min
|
Options
|
/A1
|
Alarm output 2 points (C-contact)*1*10
|
/A2
|
Alarm output 4 points (C-contact)*1
|
/A3
|
Alarm output 6 points (C-contact)*1*3
|
/A4A
|
Alarm output 12 points (A-contact)*1*3
|
/C2
|
RS-232 interface*2
|
/C3
|
RS-422A/485 interface*2
|
/C7
|
Ethernet interface
|
/F1
|
FAIL/Status output*3
|
/M1
|
Mathematical functions (including Report functions)
|
/N2
|
3 leg isolated RTD*4
|
/N3F
|
Extended input type (without Pt1000)
|
/P1
|
24 VDC/AC power supply
|
/R1
|
Remote control 8 points*5
|
/TPS2
|
24VDC transmitter power supply (2 loops)*6*10
|
/TPS4
|
24VDC transmitter power suply (4 loops)*7
|
/USB1
|
USB interface (1 port)
|
/PM1
|
Pulse input 3 points, Remote control 5 points (including Mathematical functions)*8
|
/CC1
|
Calibration correction function
|
/LG1
|
Log scale
|
/PWR1
|
Power monitor (including Mathmatical functions)*9*10
|
Note: To load data, the FX must be equipped
with a communication interface (/C2, /C3, or /C7 option) or the USB interface (/USB1 option).
*1 Any combination of /A1, /A2, /A3, and /A4A cannot be specified together.
*2 /C2 and /C3 cannot be specified together.
*3 /A3 or /A4A cannot be specified together with /F1.
*4 /N2 cannot be specified for FX1002 or FX1004.
*5 If /R1 is specified, /A4A, /TPS2, /TPS4, /PM1, or /PWR1 cannot be specified.
*6 If /TPS2 is specified, /TPS4, /A2, /A3, /A4A, /F1, /R1, or /PM1 cannot be specified.
*7 If /TPS4 is specified, /TPS2, /A1, /A2, /A3, /A4A, /F1, /R1, or /PM1 cannot be specified.
*8 If /PM1 is specified, /A4A, /M1, /R1, /TPS2, /TPS4, or /PWR1 cannot be specified.
*9 If /PWR1 is specified, /A3, /A4A, /F1, /R1, /PM1, or /M1 cannot be specified.
*10 /TPS2, /PWR1, and /A1 cannot be specified together.