Manufacturer: Yokogawa Electric Corporation
Yokogawa Field Control Unit AFV30S-A31152
Standard Specifications
Memory Protection During Power Failure Battery Battery Back-up for Main Memory: Max. 72 hours Battery Recharge Time: Min. 48 hours Communication Interface Vnet/IP Interface: Dual-redundant HKU Interface (Option) When option code /HKU is specified, a FCU fault contact is output from the HKU. Also, the environmental conditions of the cabinet connected via the HK bus and optical ESB bus can be monitored and the operating status of the HKU can be displayed on the HIS. System alarms can also be displayed. No. of Node Units Connectable Max. 13/FCU Yokogawa Field Control Unit AFV30S-A31152 The total number of ESB Bus Node Units (ANB10) and Optical ESB Bus Node Units (ANB11) that can be connected to FCU are 13 or less. Module Configuration Power Supply Module (PW481, PW482, or PW484): 2 modules for dual-redundant configuration. Processor Module (CP471 or CP461): 2 modules for dual-redundant configuration. A dual-redundant configuration is enabled by using 2 identical modules with same model code (CP471 or CP461). I/O Module (*1): Max. 8 *1: Non-standard component. Power Supply Voltage: 100-120 V AC, Frequency: 50/60 Hz Voltage: 220-240 V AC, Frequency: 50/60 Hz Voltage: 24 V DC Specify with the Suffix Code. Weight Approx. 7.0 kg (AFV30S)
Approx. 8.0 kg (AFV30D) Yokogawa Field Control Unit AFV30S-A31152
Models and Suffix Codes
Field Control Unit
Description Model AFV30S Field Control Unit (for FIO, 19-inch Rack Mountable) Suffix Codes -A Standard type (for CP471) (*1) -S Standard type (for CP461) (*3) 3 Dual-redundant Vnet/IP, single power supply 4 Dual-redundant Vnet/IP, dual-redundant power supply 1 Always 1 1 100 - 120 V AC power supply (*4) 2 220 - 240 V AC power supply (*4) 4 24 V DC power supply (*4) 0 Basic type (*5) 1 With ISA Standard G3 option (*5) 5 Basic type with no explosion protection 6 With ISA Standard G3 option and no explosion protection E Basic type with explosion protection F With ISA Standard G3 option and explosion protection 1 LFS1700 Control function for field control station (for AFV30¨/AFV40¨, Vnet/IP and FIO) (for CP461) (*6) 2 Always 2 (R6.01 or later) Option Codes /HKU With HKU interface (*7) /ATDOC Explosion Protection Manual (*8) /MRN With Marine Standards (*2)
Description
Model
AFV30S
Field Control Unit (for FIO, 19-inch Rack Mountable)
Suffix
Codes
-A
Standard type (for CP471) (*1)
-S
Standard type (for CP461) (*3)
3
Dual-redundant Vnet/IP, single power supply
4
Dual-redundant Vnet/IP, dual-redundant power supply
1
Always 1
100 - 120 V AC power supply (*4)
2
220 - 240 V AC power supply (*4)
24 V DC power supply (*4)
0
Basic type (*5)
With ISA Standard G3 option (*5)
5
Basic type with no explosion protection
6
With ISA Standard G3 option and no explosion protection
E
Basic type with explosion protection
F
With ISA Standard G3 option and explosion protection
LFS1700 Control function for field control station
(for AFV30¨/AFV40¨, Vnet/IP and FIO) (for CP461) (*6)
Always 2 (R6.01 or later)
Option
/HKU
With HKU interface (*7)
/ATDOC
Explosion Protection Manual (*8)
/MRN
With Marine Standards (*2)
Duplexed Field Control Unit
Description Model AFV30D Duplexed Field Control Unit (for Vnet/IP and FIO, 19-inch Rack Mountable) Suffix Codes -A Standard type (for CP471) (*1) -S Standard type (for CP461) (*3) 4 Dual-redundant Vnet/IP, dual-redundant power supply 1 Always 1 1 100 - 120 V AC power supply (*4) 2 220 - 240 V AC power supply (*4) 4 24 V DC power supply (*4) 0 Basic type (*5) 1 With ISA Standard G3 option (*5) 5 Basic type with no explosion protection 6 With ISA Standard G3 option and no explosion protection E Basic type with explosion protection F With ISA Standard G3 option and explosion protection 1 LFS1700 Control function for field control station (for AFV30¨/AFV40¨, Vnet/IP and FIO) (for CP461) (*6) 2 Always 2 (R6.01 or later) Option Codes /HKU With HKU interface (*7) /ATDOC Explosion Protection Manual (*8) /MRN With Marine Standards (*2)
AFV30D
Duplexed Field Control Unit (for Vnet/IP and FIO, 19-inch Rack Mountable)
AFV30S-A31152
AFV30S-A31252 AFV30S-A31452 AFV30S-A31162 AFV30S-A31262 AFV30S-A31462 AFV30S-A311E2 AFV30S-A312E2 AFV30S-A314E2 AFV30S-A311F2 AFV30S-A312F2 AFV30S-A314F2 AFV30S-A41152 AFV30S-A41252 AFV30S-A41452 AFV30S-A41162 AFV30S-A41262 AFV30S-A41462 AFV30S-A411E2 AFV30S-A412E2 AFV30S-A414E2 AFV30S-A411F2 AFV30S-A412F2 AFV30S-A414F2 AFV30S-S31151 AFV30S-S31152 AFV30S-S31251 AFV30S-S31252 AFV30S-S31451 AFV30S-S31452 AFV30S-S31161 AFV30S-S31162 AFV30S-S31261 AFV30S-S31262 AFV30S-S31461 AFV30S-S311E1 AFV30S-S311E2 AFV30S-S312E1 AFV30S-S312E2 AFV30S-S314E1 AFV30S-S314E2 AFV30S-S311F1 AFV30S-S311F2 AFV30S-S312F1 AFV30S-S312F2 AFV30S-S314F1 AFV30S-S314F2 AFV30S-S41151 AFV30S-S41152 AFV30S-S41251 AFV30S-S41252 AFV30S-S41451 AFV30S-S41452 AFV30S-S41161 AFV30S-S41162 AFV30S-S41261 AFV30S-S41262 AFV30S-S41461 AFV30S-S41462 AFV30S-S411E1 AFV30S-S411E2 AFV30S-S412E1 AFV30S-S412E2 AFV30S-S414E1 AFV30S-S414E2 AFV30S-S411F1 AFV30S-S411F2 AFV30S-S412F1 AFV30S-S412F2 AFV30S-S414F1 AFV30S-S414F2 AFV30D-A41152 AFV30D-A41252 AFV30D-A41452 AFV30D-A41162 AFV30D-A41262 AFV30D-A41462 AFV30D-A411E2 AFV30D-A412E2 AFV30D-A414E2 AFV30D-A411F2 AFV30D-A412F2 AFV30D-A414F2 AFV30D-S41101 AFV30D-S41201 AFV30D-S41401 AFV30D-S41111 AFV30D-S41211 AFV30D-S41411 AFV30D-S41161 AFV30D-S41261 AFV30D-S41451 AFV30D-S41461 AFV30D-S41152 AFV30D-S41162 AFV30D-S41252 AFV30D-S41262 AFV30D-S41452 AFV30D-S41462 AFV30D-S411E2 AFV30D-S411E1 AFV30D-S412E2 AFV30D-S412E1 AFV30D-S414E2 AFV30D-S414E1 AFV30D-S411F2 AFV30D-S411F1 AFV30D-S412F2 AFV30D-S412F1 AFV30D-S414F2 AFV30D-S414F1 AFV30D-S41151 AFV30D-S41251 AFV30D-S41451 AFV30D-S41161 AFV30D-S41261 AFV30D-S41461 AFV30D-S411E1 AFV30D-S412E1 AFV30D-S414E1